Functional and electrical safety checks:
Functional Checkout procedures
2000966-542D
Dash 3000/4000/5000
8-53
d. Ensure that the
SSID
and
SECURITY
match the wireless
network and the monitor being checked is within the wireless
coverage area.
4. On the patient monitor, select
MONITOR SETUP
>
SERVICE
MODE
.
5. Enter the password.
6. Select
MONITOR SETTINGS
>
WIRELESS LAN STATUS
.
7. Verify that
a. the
SIGNAL LEVEL (RSSI)
status is equal to or greater than
the minimum user-defined value, and
b. the
TRANSMIT RATE
status is equal to or greater than 5.5.
If the
SIGNAL LEVEL (RSSI)
is less than the minimum user-
defined value and/or the
TRANSMIT RATE
is less than 5.5, contact
the hospital IT department to check for radio interference and verify
that the access point’s radio transmission is operating optimally.
8. Close the
WIRELESS LAN STATUS
window.
NOTE
The following steps require at least one other patient monitor
connected to MC network.
9. Configure the patient monitor to view the stationary patient
monitor’s waveform as follows:
a. On the patient monitor, select
MORE MENU
>
VIEW OTHER
PATIENTS
>
SELECT ANOTHER CARE UNIT
.
b. Select the appropriate unit.
c. Select
SELECT A BED TO VIEW
.
d. Select the appropriate bed.
10. Verify that the waveform displays without any losses.
If a waveform gap or loss was spotted on the display, troubleshoot to
determine if the problem is with the wireless network card or
network.
945A
Содержание 001C 051D 003A
Страница 10: ...viii Dash 3000 4000 5000 2000966 542D ...
Страница 11: ...2000966 542D Dash 3000 4000 5000 1 1 1 Introduction ...
Страница 20: ...Introduction Service information 1 10 Dash 3000 4000 5000 2000966 542D ...
Страница 21: ...2000966 542D Dash 3000 4000 5000 2 1 2 Equipment overview ...
Страница 64: ...Equipment overview Theory of operation 2 44 Dash 3000 4000 5000 2000966 542D ...
Страница 65: ...2000966 542D Dash 3000 4000 5000 3 1 3 Installation ...
Страница 73: ...2000966 542D Dash 3000 4000 5000 4 1 4 Configuration ...
Страница 99: ...2000966 542D Dash 3000 4000 5000 5 1 5 Preventive maintenance ...
Страница 116: ...Preventive maintenance Clear the stored patient data memory 5 18 Dash 3000 4000 5000 2000966 542D ...
Страница 117: ...2000966 542D Dash 3000 4000 5000 6 1 6 Troubleshooting ...
Страница 146: ...Troubleshooting Wireless LAN 6 30 Dash 3000 4000 5000 2000966 542D ...
Страница 147: ...2000966 542D Dash 3000 4000 5000 7 1 7 Field replaceable units ...
Страница 201: ...2000966 542D Dash 3000 4000 5000 8 1 8 Functional and electrical safety checks ...
Страница 256: ...Functional and electrical safety checks Checkout procedures completion 8 56 Dash 3000 4000 5000 2000966 542D ...
Страница 257: ...2000966 542D Dash 3000 4000 5000 A 1 A Electromagnetic compatibility EMC ...
Страница 267: ...2000966 542D Dash 3000 4000 5000 B 1 B Network troubleshooting ...
Страница 273: ...2000966 542D Dash 3000 4000 5000 C 1 C Network disclosure to facilitate network risk management ...
Страница 279: ...2000966 542D Dash 3000 4000 5000 D 1 D Checklist ...
Страница 281: ......