Troubleshooting
GDL 90 Installation Manual
560-1049-02 Rev. B
5-3
"MSG 018: GPS engine has failed."
Comment:
This message indicate a problem with the internal GPS
receiver. Contact the factory.
"MSG 019: Missed ownship transmit loopback."
Comment:
There is no need to call the factory unless the problem is
persistent, or other problems are reported as well.
"MSG 020: Invalid magnetic variation file."
Comment:
The GDL 90 magnetic variation file is invalid or missing.
The GDL 90 may continue to be used. Moving map output (if used) will
not provide mag var correction. Contact the factory for assistance.
"MSG 021: Magnetic variation file out of date."
Comment:
The GLD 90 magnetic variation file has expired. The GDL
90 may continue to be used. Moving map output (if used) will not
provide mag var correction. Contact the factory for assistance.
5.2.2
Messages for External Command
The “external” command can produce Messages 060 and higher.
"MSG 060: One of antenna BITE tests has failed."
"MSG 061: All antenna BITE tests have failed."
Comment
: On the maintenance port, enter the command “log current”
for more information on which antenna has failed.
"MSG 062: Control panel is not detected."
"MSG 063: Control panel has failed (no heartbeat)."
Comment:
The Control Panel or its interface to the GDL 90 is not
working correctly. Check the Control Panel installation and APM
configuration.
"MSG 064: No valid data from the Altitude Encoder."
"MSG 065: No valid altitude available."
Comment:
The altitude encoder or its interface to the GDL 90 is not
working correctly. Check the altitude encoder installation and APM
configuration.
"MSG 066: Display has failed."
Comment:
The GDL 90 is not receiving Initialization messages from
the display. Check the display installation and its configuration, and the
APM configuration.
"MSG 067: No response from APM."
Comment:
The APM is not communicating with the GDL 90. Check the
APM installation (flying wires connected to the correct pins on P1).
Contact the factory if the problem cannot be resolved.
"MSG 068: ADC/AHRS interface timeout."
Comment:
The GDL 90 is not receiving the expected ARINC words
from the ADC or AHRS. Check the equipment installation and wiring,
and the APM configuration. Contact the factory if the problem cannot
be resolved.
Содержание GDL 90
Страница 1: ...GDL 90 UAT Data Link Sensor Installation Manual October 2006 560 1049 02 Rev B ...
Страница 8: ...Table of Contents vi 560 1049 02 Rev B GDL 90 Installation Manual Notes ...
Страница 42: ...Installation Procedures 2 24 560 1049 02 Rev B GDL 90 Installation Manual Figure 2 11 GDL 90 Center of Gravity ...
Страница 44: ...Installation Procedures 2 26 560 1049 02 Rev B GDL 90 Installation Manual Notes ...
Страница 48: ...Limitations 560 1049 02 Rev B GDL 90 Installation Manual 3 4 Notes ...
Страница 62: ...Post Installation Configuration and Checkout 560 1049 02 Rev B GDL 90 Installation Manual 4 14 Notes ...
Страница 76: ...Periodic Maintenance 560 1049 02 Rev B GDL 90 Installation Manual 6 2 Notes ...
Страница 80: ...Certification Data A 4 560 1049 02 Rev B GDL 90 Installation Manual Notes ...
Страница 82: ...Serial Interface Specifications B 2 560 1049 02 Rev B GDL 90 Installation Manual Notes ...
Страница 83: ...Serial Interface Specifications GDL 90 Installation Manual 560 1049 02 Rev B B 3 ...
Страница 84: ...Serial Interface Specifications B 4 560 1049 02 Rev B GDL 90 Installation Manual ...
Страница 85: ...Serial Interface Specifications GDL 90 Installation Manual 560 1049 02 Rev B B 5 ...
Страница 86: ...Serial Interface Specifications B 6 560 1049 02 Rev B GDL 90 Installation Manual Notes ...
Страница 87: ...Interconnect Diagrams GDL 90 Installation Manual 560 1049 02 Rev B C 1 APPENDIX C Interconnect Diagrams ...
Страница 88: ...Interconnect Diagrams C 2 560 1049 02 Rev B GDL 90 Installation Manual Notes ...
Страница 92: ...Interconnect Diagrams C 6 560 1049 02 Rev B GDL 90 Installation Manual This Page Intentionally Left Blank ...
Страница 95: ......
Страница 96: ......