Troubleshooting
560-1049-02 Rev. B
GDL 90 Installation Manual
5-2
5.2
Collecting Additional Information
This section contains a summary of the messages produced by the “service” and “external” Maintenance
port commands. Some brief comments are included for each group of commands that may help in
troubleshooting efforts.
5.2.1
Messages for Service Command
The “service” command can produce Messages 001 up to 059.
"MSG 001: Invalid messages from Radio Controller"
"MSG 002: No messages from Radio Controller."
"MSG 003: No response from Radio Controller."
Comment:
These messages indicate a problem with the internal radio
assembly. Contact the factory.
"MSG 004: Invalid transmit processing time."
Comment:
This indicates a temporary software timing limitation. There
is no need to contact the factory unless the problem is persistent.
"MSG 005: Invalid ownship transmit loopback."
Comment:
This indicates a connection problem between the UAT
transmitter and receiver. Contact the factory.
"MSG 006: Transmit output power failure."
"MSG 007: No PLL lock indication.”
Comment:
Persistent occurrence of these messages indicates a problem
with the internal radio assembly. Contact the factory.
"MSG 008: NVRAM battery low."
Comment:
The GDL 90 internal battery needs to be replaced. Contact
the factory.
"MSG 009: APM map version is old."
Comment:
The GDL 90 software is a newer version than the APM was
configured with. The “APMinit” procedure should be used to update the
APM map, and correct any undefined settings.
"MSG 010: APM Invalid Product ID."
"MSG 011: Invalid value in the APM ICAO address field."
"MSG 012: Invalid value in the APM Aircraft Category field."
"MSG 013: Invalid value in the APM antenna mode field."
"MSG 014: Invalid value in the APM grounded antenna field."
"MSG 015: APM CRC check has failed."
"MSG 016: Receive invalid messages from APM."
Comment:
These messages all indicate a problem with the APM data
contents. Contact the factory.
Содержание GDL 90
Страница 1: ...GDL 90 UAT Data Link Sensor Installation Manual October 2006 560 1049 02 Rev B ...
Страница 8: ...Table of Contents vi 560 1049 02 Rev B GDL 90 Installation Manual Notes ...
Страница 42: ...Installation Procedures 2 24 560 1049 02 Rev B GDL 90 Installation Manual Figure 2 11 GDL 90 Center of Gravity ...
Страница 44: ...Installation Procedures 2 26 560 1049 02 Rev B GDL 90 Installation Manual Notes ...
Страница 48: ...Limitations 560 1049 02 Rev B GDL 90 Installation Manual 3 4 Notes ...
Страница 62: ...Post Installation Configuration and Checkout 560 1049 02 Rev B GDL 90 Installation Manual 4 14 Notes ...
Страница 76: ...Periodic Maintenance 560 1049 02 Rev B GDL 90 Installation Manual 6 2 Notes ...
Страница 80: ...Certification Data A 4 560 1049 02 Rev B GDL 90 Installation Manual Notes ...
Страница 82: ...Serial Interface Specifications B 2 560 1049 02 Rev B GDL 90 Installation Manual Notes ...
Страница 83: ...Serial Interface Specifications GDL 90 Installation Manual 560 1049 02 Rev B B 3 ...
Страница 84: ...Serial Interface Specifications B 4 560 1049 02 Rev B GDL 90 Installation Manual ...
Страница 85: ...Serial Interface Specifications GDL 90 Installation Manual 560 1049 02 Rev B B 5 ...
Страница 86: ...Serial Interface Specifications B 6 560 1049 02 Rev B GDL 90 Installation Manual Notes ...
Страница 87: ...Interconnect Diagrams GDL 90 Installation Manual 560 1049 02 Rev B C 1 APPENDIX C Interconnect Diagrams ...
Страница 88: ...Interconnect Diagrams C 2 560 1049 02 Rev B GDL 90 Installation Manual Notes ...
Страница 92: ...Interconnect Diagrams C 6 560 1049 02 Rev B GDL 90 Installation Manual This Page Intentionally Left Blank ...
Страница 95: ......
Страница 96: ......