Page 7-48
Cirrus Perspective™ Line Maintenance Manual
Rev. E
190-00920-00
7.5.2.3
Static
Port
Vertical
Speed
(Rate
of
Climb)
Test
1.
Use
the
ADTS
to
change
the
altitude
at
the
rates
shown
in
the
table
below.
2.
Wait
for
the
ADTS
to
report
that
target
rates
have
been
achieved.
3.
Verify
that
the
rate
of
climb
reported
by
the
vertical
speed
field
on
the
PFD
is
within
the
tolerances
specified
in
the
table
below:
Vertical
Speed,
feet/minute
Allowed
tolerance,
±feet/minute
2000
100
0
45
‐
2000
100
4.
Press
the
“SENSOR”
PFD
softkey
and
then
select
ADC2
(if
equipped).
Repeat
steps
1
‐
3.
7.5.2.4
OAT
Probe
Test
Check
the
outside
air
temperature
(OAT)
measurement
shown
on
the
PFD
to
make
sure
it
reads
ambient
temperature.
7.5.2.5
Second
OAT
Probe
Test
in
Dual
ADC
Installations
Select
the
‘SENSORS’
softkey
on
the
PFD
then
select
ADC2
to
view
the
second
OAT
in
a
dual
ADC
equipped
installation.
Make
sure
it
reads
ambient
temperature.