Explosive, toxic and hot gases and molten sulfur may be released once the
stream jacketed ball valve is opened. All company and/or regulatory agency
safety procedures and rules should be adhered to. Breathing apparatus and
personal protective equipment (ie. gloves, coveralls and protective eye
wear) should be worn and a safety person(s) should be observing. Do not
take unnecessary risks even if you believe the tailgas line to be at negative
pressure.
5. Tighten the packing gland and connect the tubing to the probe as shown in Figure 7.
Make sure the three valves on the left of the oven enclosure (V1, V3, V5) are in the
open position as shown in Figure 7. Close the two block valves indicated on the right
side of Figure 8 (V2, V4). Install the probe RTD in the location indicated in Figure 7.
Figure 7: Oven Enclosure Tubing Reinstalled
If the connections are leak-tight and company safety personnel have deemed
the atmosphere to be safe, breathing apparatus may now be removed.
6. Reinstall the hole plug at the top of the the oven cabinet.
Return to the closed position
Probe
RTD
Installation
Location