MCT-CM
9
The MCT-CM controller includes the following features:
ACCESSIBILITY
•
Touch screen, “Smart Device” user interface (UI) with
30,000-hour LED display
•
Built in configuration software; no external software or
PC required
•
Email, SMS, FTP, FileWeb, DataWeb, VNC and Web
functionality standard
•
Remote View/Control using PC, Tablet or Smartphone.
•
Modbus RTU RS232/485 serial and Modbus TCP user
communication interfaces for 3
rd
party software or
hardware access.
•
National time server connectivity with daylight savings.
COMMAND BAR ICONS
NAVIGATION, HELP & HOME
The Master Command Bar located on the top of the
display provides easy & intuitive 1-touch access from
anywhere in the system to Navigation, Help and
configured Home view.
Home brings the user back to the system “Home” view.
The Home icon can be configured for the following
standard views:
•
Loop view: includes PV & SP digital display, PV
min/max, PID % Output, manual (event) operation,
ramp/soak program access and more.
•
Overview: all loops, monitors, program, alarm and
event status
•
Chart view: (trend up to the last 24 hours from system
RAM) supporting 8 trends with up to 8 values per trend
•
Alarm view or Alarm File
Help offers content sensitive text for every view / page
in one of 11 supported languages chosen by the user.
Navigation provides access to the configured menu
system, traditional drop down or icon.
SECURITY AND AUDIT TRAIL
•
Supports up to 30 users over four user groups with
access to 50+ functions restricted by user group.
•
Supports password aging and verification.
•
Operator Audit Trail provides history for all user activity
that includes date, time, user name and action; i.e. Loop
SP change from 55.2 to 103.5.
PROGRAM RAMP/SOAK
•
Up to ten loops
•
Start: via touch screen or Event input
•
Program Name: 16-character naming convention
•
Global Program Configuration:
- Guaranteed Soak & Ramp band
- Power Fail / Recovery: Hold, continue, restart,
resume or static mode.
•
Program Segments: (maximum of 99)
•
Guaranteed Soak & Ramp per step
•
Events: up to 32 events per step
•
Jump-To Step: configurable per step
•
Programmable “wait for” step advance logic includes
digital inputs, loops and monitor points.
ALARMS
• Maximum of 30 alarms configurable to any loop/monitor
in the system.
• Alarm Types: Process, Deviation and Percent Output
low, high or both.
• Alarm Modes: Latching, Silent and Inhibit on startup.
• Alarms can be configured to activate a digital output
and/or defeat digital outputs when active.
DATA ACQUISITION
• Data log up to ten control loops (PV, SP and % out) and
up to 15 optional monitor points (up to 25 PV inputs total).
• File name: Free form 16 character appended by
time/date or the profile name if started with a profile.
• File Start/Stop: user on-demand, on system boot or
profile ramp-soak start/end.
• Data Log interval: configurable 2 seconds to 31 minutes.
• File Interval: configurable to set time in days (1 to 31) to
end and start a new file.
• ID#1 and ID#2 fields allow user to enter specific
information such as a batch and/or lot information that is
associated with the data file.
• Operator
Comments/Events:
Unlimited
operator
comments/events linked to each file
• File Type: Data Log files are saved in .csv format.
• Digital Signatures: Automatic system as well as user
entered signatures.
• Historical Data Viewer: View data log fi les on the display.
Chart is auto-scaled on an X & Y axis for time and units.
• Meets the requirements for:
- CFR21 Part 11
- AMS2750E
Configurable Digital IO
Digital Inputs (DI): CPU includes 8 inputs with optional
8
input card for maximum of 16 digital inputs.
• Digital inputs are configurable as a time delay (timers),
alarm inputs, program run/stop control, output disable
and more.
Digital Outputs (DO): CPU includes 8 outputs with
optional 8 or 16 output
card for maximum of 24 outputs.
• Digital outputs are configurable as event outputs or
system control outputs and include on/off delay times
and cycle timers.
• Output “on” times and off/on cycles are tracked and can
be used to generate service alerts for hours of
operation.
Configurable Analog IO
•
Remote Setpoint: Cards accept two 4-20mA or 2-10Vdc
inputs to be utilized as a set point value for a specified
loop control.
•
Retransmission: Cards have one 4-20mA or 0-10VDC
signals configurable as PV, Setpoint or % Out values
from a specified loop control.
Maximum number of cards is 7: 14 remote set point
inputs and 7 retransmitted PV, SP or %Out values.
Содержание MCT-CM
Страница 1: ...MCT CM User Manual MCT CM User Manual Rev C August 2022 V1 2eCM30 V1 3eCM22 Supersedes May 2021...
Страница 20: ...MCT CM 20...
Страница 24: ...MCT CM 24...
Страница 45: ...MCT CM 45...
Страница 187: ...MCT CM 187...
Страница 227: ...MCT CM 227 A 4 Control Module Specifications Main CPU...
Страница 228: ...MCT CM 228...
Страница 229: ...MCT CM 229...
Страница 230: ...MCT CM 230...
Страница 231: ...MCT CM 231 Analog I O Card...
Страница 232: ...MCT CM 232...
Страница 233: ...MCT CM 233 Digital Input Card...
Страница 234: ...MCT CM 234...
Страница 235: ...MCT CM 235 Digital Output Card...
Страница 236: ...MCT CM 236...
Страница 237: ...MCT CM 237 Dual Communications Card Barcode and Remote Display Communication Cartridges...
Страница 238: ...MCT CM 238 A 5 Power Supply Specifications...
Страница 239: ...MCT CM 239...
Страница 240: ...MCT CM 240 A 6 Power On Delay Relay Specifications GE1A C10HA110...
Страница 241: ...MCT CM 241...