![Furukawa Unic URW376C4U -T Series Скачать руководство пользователя страница 97](http://html1.mh-extra.com/html/furukawa-unic/urw376c4u-t-series/urw376c4u-t-series_operation-and-maintenance-manual_2349552097.webp)
12-5
MAINTENANCE AND INSPECTION OF CARRIER
Check engine oil quantity before starting the
engine with the crawler crane parked on a flat
ground.
If the engine has been started, check the oil
level after at least more than 5 minutes when
the engine had been stopped.
2.
◆
Check for engine oil quantity
/ Filling up
★
Wipe up spilled oil thoroughly after filling it up as it may cause the
fire.
WARNING
★
Replace engine oil and fuel filter element after 100 hours (1 month) of
operation, then every 250-hour operation (3 months) thereafter.
CAUTION
• Extract the oil level gauge and wipe it off
with a piece of clean rag.
Insert the gauge again slowly then extract
it to check the level wet with oil.
(Check the oil for contamination and viscos-
ity at the same time.)
• If oil level is found too low, supply it from
the filling port.
Filling port
Oil level gauge
Upper limit
Lower limit