12-24
MAINTENANCE AND INSPECTION OF CARRIER
6
Remove the cover to take out the suc-
tion strainer after draining.
Suction strainer
Suction strainer
7
Remove dust stuck to the strainer and
wash it with nonflammable wash oil.
Replace the strainer if it is found damaged.
9
Check the O-ring on the cover and
replace it with new one if it is found
damaged.
Cover the drain plug with a new sealing tape.
8
Check if there is foreign object depos-
ited in the tank and wash inside of the
tank with a wash oil.
10
Fit the cleaned strainer to tighten
the drain plug.
Then replace the line filter element.
Cover