SPARC Enterprise T5120 and T5220 Servers Product Notes • April 2010
6752910
After a host power-on instruction is executed
from ILOM, the POST (self-diagnostics test) may
not start, and processing may not go to OS boot
processing or the
ok
prompt for OpenBoot
PROM (OBP).
For details, see
After turning off the power to the host, wait at
least three minutes before turning it on again.
6726663
In ILOM mode, or through access to the ILOM
Web, it may be possible to change the system
time when the system is powered on.
In ILOM mode, be sure not to change the
properties displayed below at power on so as
not to change the system time directly or enable
NTP services.
->
show /SP/clock
/SP/clock
Targets:
Properties:
datetime = Wed Dec 3 06:22:48 2008
usentpserver = disabled
Commands:
cd
set
show
->
n/a
The following error message may be output
during POST. Since the error has no impact on
system operation, you can ignore the message.
0:0:0>Begin: Block Mem Test
0:0:0>Block Mem Test 00000000. 02000000-
>00000008. 00000000
0:0:0>
FBR Error Tally Branch
3 = 2
= Indefinite value
None.
TABLE 3-3
Firmware, ILOM, POST, and SP Issues
(Continued)
CR
Description
Workaround