Appendix A
Fixed Issues
121
If your server experiences this panic, perform one or more of the following
workarounds:
■
To ensure that the system reboots and continues to function after a panic,
configure the server to automatically reboot using one of the following methods:
■
Using the ILOM CLI:
■
Using the ALOM CMT compatibility CLI:
■
To eliminate the possibility of the panic, disable the USB (only perform this
workaround if you do not use USB devices, including the built-in DVD drive):
■
Using the ILOM CLI:
■
Using the ALOM CMT compatibility CLI:
All devices on the USB will be disabled, including the DVD drive. Be aware that
the service processor will generate a fault and turn on the fault LED.
If you need to enable the USB, use the following commands:
■
Using the ILOM CLI:
■
Using the ALOM CMT compatibility CLI:
Information Missing From
prtpicl
and
prtdiag
Commands (CR 6586624)
This issue is resolved by updating the system firmware to 7.0.9 or later.
->
set /HOST/bootmode script="setenv auto-boot? true"
->
set /HOST/bootmode script="setenv auto-boot-on-error? true"
sc>
bootmode bootscript="setenv auto-boot? true"
sc>
bootmode bootscript="setenv auto-boot-on-error? true"
->
set /SYS/MB/PCIE-IO/USB component_state=Disabled
sc>
disablecomponent /SYS/MB/PCIE-IO/USB
->
set /SYS/MB/PCIE-IO/USB component_state=Enabled
sc>
enablecomponent /SYS/MB/PCIE-IO/USB
Содержание SPARC Enterprise T5120
Страница 10: ...x SPARC Enterprise T5120 and T5220 Servers Product Notes April 2010 ...
Страница 20: ...8 SPARC Enterprise T5120 and T5220 Servers Product Notes April 2010 ...
Страница 84: ...72 SPARC Enterprise T5120 and T5220 Servers Product Notes April 2010 ...
Страница 149: ......
Страница 150: ......