90
SPARC Enterprise T5120 and T5220 Servers Product Notes • April 2010
6692478
Failures may occur in ILOM functions such as
user account management if a prohibited
character like "#", "+", or ":" is used for the first
character of an ILOM user account.
Note - Fixed in System Firmware 7.2.2.e or later.
None.
When the user account can be deleted, the ILOM
can be recovered by deleting the user account.
When the user can not be deleted, reset the ILOM
configuration to factory defaults to recover the
ILOM.
For the details about procedures and valid
characters for ILOM user accounts, see the
"
Integrated Lights Out Manager 2.0 User's Guide
."
6781815
After the ILOM reset or the power cable removal
and insertion, when the server powered on,
Solaris OS startup at the
ok
prompt of OBP
(OpenBoot PROM) using the
boot
command
may fail.
Error output example:
{0} ok boot
ERROR: All device paths in boot-
device have failed. (*)
{0} ok
It cannot refer to the device paths that
configured in the OBP environmental variable
boot-device
and fails to start Solaris OS.
Note - Fixed in System Firmware 7.2.2.e or later.
After the ILOM reset or the power cable removal
and insertion, when you power on the server,
check the OBP environmental variable. Especially,
in case the OBP environmental variable
use-
nvramrc?
has been set to true, it is necessary in
advance of starting the OS to see the
ok
prompt
and check that
use-nvramrc?
has been set to
true and then execute the
boot
command.
Confirmation example:
{0} ok printenv use-nvramrc?
use-nvramrc? = true
{0} ok
6782508
The
/SP/powermgmt/policy
property has
been disabled.
Note - Fixed in System Firmware 7.2.2.e or later.
To
/SP/powermgmt/policy
, the following
properties have become available.
-
Performance
The system is allowed to use all the power that is
available.
-
Elastic
The system power usage is adapted to the current
utilization level. For example, power up or down
just enough system components to keep relative
utilization at 70% at all times, even if workload
fluctuates.
This property is enabled only in the logical
domain (LDoms) environment.
In case you are not in the logical domain (LDoms)
environment, or in case that the logical domain
(LDoms) configuration is the factory-default, the
property setting is available but cannot utilize its
power consumption control function.
TABLE A-3
Fixed Firmware, ILOM, POST, and SP Issues
(Continued)
CR
Description
Workaround
Содержание SPARC Enterprise T5120
Страница 10: ...x SPARC Enterprise T5120 and T5220 Servers Product Notes April 2010 ...
Страница 20: ...8 SPARC Enterprise T5120 and T5220 Servers Product Notes April 2010 ...
Страница 84: ...72 SPARC Enterprise T5120 and T5220 Servers Product Notes April 2010 ...
Страница 149: ......
Страница 150: ......