44
SPARC Enterprise T5120 and T5220 Servers Product Notes • April 2010
For DC Input Power Models, /PS0/AC_POK Is
Displayed (CR 6815369)
For DC input power models, /PS0/AC_POK and /PS0/DC_POK identify sensors in
the power supply units. /PS0/AC_POK does not represent an AC power supply
unit.
For example, the following event log is collected when the DC power cable is
disconnected or reconnected:
[When the DC power cable is disconnected]
[When the DC power cable is reconnected]
Workaround: None
Sep 29 12:50:47: Chassis |major : "Host has been powered on"
Sep 29 12:54:35: Chassis |major : "Host is running"
Sep 29 12:54:51: Chassis |critical: "Host has been powered off" * There is no
"Host has been powered on." log entry after this.
sc>
IPMI |minor : "ID = 1cec : 02/06/2009 : 04:00:26 : Power Supply
: /PS0/AC_POK : State Deasserted" <--(*)
IPMI |minor : "ID = 1ced : 02/06/2009 : 04:00:26 : Power Supply
: /PS0/DC_POK : State Deasserted"
IPMI |minor : "ID = 1cee : 02/06/2009 : 04:00:26 : Power Supply
: /PS0/FAIL : State Asserted"
IPMI |minor : "ID = 1cef : 02/06/2009 : 04:00:59 : Power Supply
: /PS0/AC_POK : State Asserted" <--(*)
IPMI |minor : "ID = 1cf0 : 02/06/2009 : 04:00:59 : Power Supply
: /PS0/DC_POK : State Asserted"
IPMI |minor : "ID = 1cf1 : 02/06/2009 : 04:00:59 : Power Supply
: /PS0/FAIL : State Deasserted"
Содержание SPARC Enterprise T5120
Страница 10: ...x SPARC Enterprise T5120 and T5220 Servers Product Notes April 2010 ...
Страница 20: ...8 SPARC Enterprise T5120 and T5220 Servers Product Notes April 2010 ...
Страница 84: ...72 SPARC Enterprise T5120 and T5220 Servers Product Notes April 2010 ...
Страница 149: ......
Страница 150: ......