28
SPARC Enterprise T5120 and T5220 Servers Product Notes • April 2010
6585114
During automated testing, the SP could
encounter problems with
useradd
and
usershow
commands, followed by the failure of
all login attempts.
AC power cycle the system.
6585292
Some extraneous and misleading warning
messages are displayed in the output of the
ILOM
reset
/SP
command and of the ALOM
CMT compatibility
resetsc
command.
For an except of the misleading messages, see
“Resetting the SP Produces Extraneous Warning
Messages (CR 6585292)” on page 40
Ignore the extraneous warning messages.
6595955
If a component is not physically present on a
system (such as the fan module), the status field
in the
prtdiag -v
(Environmental Status
Section) output shows no value and is blank.
6596430
If the socketed EEPROM (SCC) is replaced, the
SP does not always read some SP properties
from the new EEPROM.
If the SP configuration variable
sc_backupuserdata
is set to
false
, the
following user configuration values are not
backed up to the socketed EEPROM:
if_emailalerts, mgt_mailhost,
mgt_mailalert, sc_customerinfo,
sc_powerondelay, sc_powerstatememory,
sc_backupuserdata
Manually copy the user settings before replacing
the motherboard in a motherboard swap
scenario. After the swap is complete, manually
set the user parameters.
6596594
Changed OpenBoot NVRAM parameters do not
take affect after a
resetsc.
If the service processor is reset while the control
domain is at the
ok
prompt, OpenBoot PROM
will permanently lose its ability to store
nonvolatile LDoms variables or security keys
until the host has been reset. Guest domains are
not affected by this problem. Attempts to update
LDoms variables or security keys results in the
following warning messages:
WARNING: Unable to update LDOM Variable
WARNING: Unable to store Security key
After changing variables, reset the control
domain using the
reset-all
command.
TABLE 3-3
Firmware, ILOM, POST, and SP Issues
(Continued)
CR
Description
Workaround
Содержание SPARC Enterprise T5120
Страница 10: ...x SPARC Enterprise T5120 and T5220 Servers Product Notes April 2010 ...
Страница 20: ...8 SPARC Enterprise T5120 and T5220 Servers Product Notes April 2010 ...
Страница 84: ...72 SPARC Enterprise T5120 and T5220 Servers Product Notes April 2010 ...
Страница 149: ......
Страница 150: ......