Appendix A
Fixed Issues
99
2. Enter #. to escape to the SP ILOM CLI. The escape sequence is not echoed.
3. Enter the
break
command as follows.
Log back into the Solaris host with the
console
command.
Refer to the
Integrated Lights Out Manager 2.0 User’s Guide
and the
Integrated Lights
Out Management (ILOM) Supplement for SPARC Enterprise T5120 and T5220 Servers
for
details on how to use the
break
command from the SP CLIs.
The
showfaults
Command Shows the
Motherboard as Faulty Instead of the DIMM (CR
6582853)
This issue is resolved by updating the system firmware to 7.1.6.d or later.
In a system with DIMMs or PCIe adapters that have been faulted by PSH (Predictive
Self-Healing) diagnosis on the host, the ALOM
showfaults
command displays the
faulty FRU as the motherboard (
/SYS/MB
) instead of the DIMM or PCIe adapter.
This problem will occur for the following PSH Message-IDs (MSGID):
■
SUN4V-8000-E2
■
SUN4V-8000-D
■
SUN4-8000-4P
■
SUN4-8000-A2
■
SUN4-8000-75
■
SUN4-8000-9J
■
SUN4-8000-D4
■
PCIEX-8000-0A
■
PCIEX-8000-DJ
Solaris-host-prompt>
#.
->
->
set /HOST send_break_action=break
->
->
start /SP/console
Are you sure you want to start /SP/console (y/n)?
y
Serial console started. To stop, type #.
c)ontinue, s)ync, r)eboot, h)alt?