194
Upgrade and Maintenance Manual
CX400 M4
Appendix
12.3 Minimum startup configuration
If the server does not start up or other problems occur, it may be necessary to
take the system down to its most basic configuration in order to isolate the
defective component.
The minimum startup configuration consists of the following components and
cables:
Ê
"Shutting down the server node" on page 40
Ê
"Disconnecting the power cord" on page 41
Ê
Take the system down to its minimum startup configuration.
Ê
"Connecting the power cord" on page 71
Ê
"Switching on the server node(s)" on page 72
V
CAUTION!
Since the fan module is not included in the minimum startup
configuration, the server must be shut down immediately after the
diagnostic process is complete (POST phase has been passed).
The minimum startup configuration must be used exclusively for
diagnostic purposes by maintenance personnel, never in daily
operation!
Field Replaceable Units (FRU)
Component
Notes and reference
1 Server node CX2550 M4 /
CX2560 M4 or CX2570 M4
1 PSU
Table 10: Minimum startup configuration - components
Cable
Notes and reference
Power cable
Table 11: Minimum startup configuration - cables
Содержание PRIMERGY CX400 M4
Страница 6: ...Upgrade and Maintenance Manual CX400 M4 ...
Страница 126: ...126 Upgrade and Maintenance Manual CX400 M4 Hard disk drives HDD solid state drives SSD and 2 5 inch PCIe SSD ...
Страница 156: ...156 Upgrade and Maintenance Manual CX400 M4 Midplane kit ...
Страница 176: ...176 Upgrade and Maintenance Manual CX400 M4 Front panel ...
Страница 178: ...178 Upgrade and Maintenance Manual CX400 M4 Cabling 11 2 Cabling Figure 100 Cabling 1 Front panel 2 Midplane kit ...