CX400 M4
Upgrade and Maintenance Manual
71
Basic hardware procedures
4.13 Connecting the power cord
Connecting the power cord (AC PSU)
V
CAUTION!
The server supports a mains voltage in the range of 100 VAC to
240 VAC. You may only operate the server if its rated voltage range
corresponds to the local mains voltage.
Ê
If applicable, connect the mains plugs to power outlets of the rack socket
strip.
I
To provide true phase redundancy, the second PSU should be
connected to a different AC power source from the other PSU. If one
AC power source should fail, the server will still continue to run.
Ê
Connect the power cords to the PSUs.
Ê
Ensure that the status indicator on the PSU is lit green (see section
"Indicator on hot-plug PSU" on page 192
Figure 35: Example: Locking the cable clamp of a PSU
Ê
Loop the cable tie around the power connector and the handle of the hot-
plug PSU (1).
Ê
Pull tight the cable tie (2) to secure the power connector.
I
It takes 60 seconds to become a standby mode after connecting a server
to the mains.
Содержание PRIMERGY CX400 M4
Страница 6: ...Upgrade and Maintenance Manual CX400 M4 ...
Страница 126: ...126 Upgrade and Maintenance Manual CX400 M4 Hard disk drives HDD solid state drives SSD and 2 5 inch PCIe SSD ...
Страница 156: ...156 Upgrade and Maintenance Manual CX400 M4 Midplane kit ...
Страница 176: ...176 Upgrade and Maintenance Manual CX400 M4 Front panel ...
Страница 178: ...178 Upgrade and Maintenance Manual CX400 M4 Cabling 11 2 Cabling Figure 100 Cabling 1 Front panel 2 Midplane kit ...