CX400 M4
Upgrade and Maintenance Manual
185
Appendix
12.2.1.1 Indicators on the front panel (enclosure-related)
PSU CSS indicator (orange)
–
Lights up orange
if a hot-plug PSU prefailure event has been
detected that requires (precautionary) service intervention.
–
Flashes orange
if a hot-plug PSU error was detected that
requires service intervention.
–
Does not light
up if there is no critical event.
I
To examine, which hot-plug PSU is affected, refer to the
indicator on hot-plug PSU.
FAN CSS indicator (orange)
–
Lights up orange
if a hot-plug fan module prefailure event
has been detected that requires (precautionary) service
intervention.
–
Flashes orange
if a hot-plug fan module error was detected
that requires service intervention.
–
Does not light
up if there is no critical event.
I
To examine, which fan module is affected, refer to the
diagnostic panel on the cover of the server enclosure.
Global error indicator (orange)
–
Lights up orange
if a prefailure event has been detected that
requires (precautionary) service intervention.
–
Flashes orange
if an error was detected that requires service
intervention.
–
Does not light up
if there is no critical event.
If the event is still acute after a power cycle, the indicator is
activated after the restart.
The indicator also lights up in standby mode.
You can find more details on the indicated errors in the System
Event Log (SEL), in the ServerView Operations Manager or via
the iRMC S5's Web interface.
PSU
FAN
!
Содержание PRIMERGY CX400 M4
Страница 6: ...Upgrade and Maintenance Manual CX400 M4 ...
Страница 126: ...126 Upgrade and Maintenance Manual CX400 M4 Hard disk drives HDD solid state drives SSD and 2 5 inch PCIe SSD ...
Страница 156: ...156 Upgrade and Maintenance Manual CX400 M4 Midplane kit ...
Страница 176: ...176 Upgrade and Maintenance Manual CX400 M4 Front panel ...
Страница 178: ...178 Upgrade and Maintenance Manual CX400 M4 Cabling 11 2 Cabling Figure 100 Cabling 1 Front panel 2 Midplane kit ...