CX400 M4
Upgrade and Maintenance Manual
43
Basic hardware procedures
4.4.2
Extending the server enclosure out of the rack
Figure 3: Extending the server enclosure out of the rack (A).
Ê
While pressing the locking levers (1) on both sides of the enclosure use the
brackets (2) to pull the enclosure out of its lock.
Ê
Pull the server enclosure out of the rack until it locks in place.
V
CAUTION
Do not use the extended server enclosure as a surface on which to put
things or as a work surface, and strictly avoid leaning on or against it.
4.4.3
Removing the server enclosure out of the rack
V
CAUTION!
At least two people are needed to lift the CX400 M4 chassis out of the
rack cabinet.
For Japan, according to the following procedures.
If you remove the CX400 M4 server enclosure out of the rack, remove all
HDD, PSU and Server Node from the server enclosure.