background image

www.ventev.com/infra

[email protected]

800.851.4965

This guide is to provide basic troubleshooting for the 

Rajant KM3-ES-2450-AC NEMA 4X  enclosure 

system, SKU  #236606. The guide assumes that the 

enclosure system has been installed in accordance 

with the local jurisdiction’s regulations for hazardous 

environments. Please note that some steps have the 

potential to create electrical sparks or arcing if not 

performed properly. Only personnel certified and/or 

trained in the local jurisdiction’s regulations for 

hazardous environments should perform the 

operations outline in this guide.

Equipment Required for Troubleshooting

• Digital multimeter with probes
• CAT6 Ethernet cable
• Laptop
• Rajant BC Commander software 

Troubleshooting Guide for the

KM3-ES-2450-AC NEMA 4X Enclosure System for Rajant

KM3-ES-2450-AC NEMA 4X Enclosure System

TESSCO Sku 236606

Troubleshooting Process

1. Place the multimeter leads to the LINE  and NEUTRAL  terminal blocks (LINE is the blue terminal blocks with 

black wires; NEUTRAL  is the white terminal blocks with white wires; GND is the green terminal block with 

green wires).

2.  Verify that the voltage is between 90 ~ 264 Vac. If the voltage is outside this range, then check the 

source voltage and adjust so that it is in the input voltage range of the PoE power supply.

Отзывы: