5.3 Host Commands
(40) READ MULTIPLE EXT (X '29')
•
Description
This command is the extended command of the READ MULTIPLE command.
The LBA specification is increased from 28 bits to 48 bits, and the maximum
number of sectors that can be transferred by a single command is changed from
100h to 10000h. Other command controls are the same as those of the READ
MULTIPLE command.
•
Error reporting conditions
At command issuance (Shadow Block Registers setting contents)
(1) The command was issued in CHS mode (ST = 51h, ER = 04h).
The other error reporting conditions are the same as those of the READ
MULTIPLE command.
CM
0 0 1 0
1
1 0 0
DH
1 L 1 x
xx
CH EXP
CH
CL EXP
CL
SN EXP
LBA (39-32)
Sector count (15-8)
xx
SN
SC EXP
SC
FR EXP
FR
LBA (47-40)
LBA (23-16)
LBA (15-8)
LBA (31-24)
LBA (7-0)
Sector count (7-0)
xx
At command completion (Shadow Block Registers contents to be read)
ST Status
information
DH
1
1 L
x
xx
CH EXP
CH
CL EXP
CL
SN EXP
SN
SC EXP
SC
ER
LBA (47-40)
LBA (23-16)
LBA (39-32)
LBA (15-8)
LBA (31-24)
LBA (7-0)
xx
xx
Error information
C141-E280
5-147
Содержание MHZ2080BJ
Страница 4: ...This page is intentionally left blank ...
Страница 12: ...This page is intentionally left blank ...
Страница 44: ...This page is intentionally left blank ...
Страница 56: ...This page is intentionally left blank ...
Страница 253: ...5 4 Command Protocol Device Host RegHD PIO Setup DATA Figure 5 14 PIO data in command protocol C141 E280 5 179 ...
Страница 284: ...This page is intentionally left blank ...
Страница 300: ...This page is intentionally left blank ...
Страница 304: ...This page is intentionally left blank ...
Страница 306: ...This page is intentionally left blank ...
Страница 314: ...This page is intentionally left blank ...
Страница 316: ...This page is intentionally left blank ...
Страница 318: ......
Страница 319: ......
Страница 320: ......