Interface
•
SCT COMMAND SET (SN = E0h, FR = D6)
This command transfers Key Sector Format in 512 bytes including the action code
shown in Table 5.26 to the device, and executes each function to show in Table
5.27 to Table 5.30.
28-bit command
At command issuance (Shadow Block Registers setting)
CM 1
0
1
1
0
0
0
0
DH x
x
x
DV
xx
CH
CL
SN
SC
FR
Key (C2h)
Key (4Fh)
E0h
01h
D6h
At command completion (Shadow Block Registers contents to be read)
ST Status
information
DH
x x x
DV
xx
CH
CL
SN
SC
ER
xx
xx
xx
xx
Error information
5-76