![Fuji Electric FVR-C11S-7EN Series Скачать руководство пользователя страница 84](http://html1.mh-extra.com/html/fuji-electric/fvr-c11s-7en-series/fvr-c11s-7en-series_instruction-manual_2341873084.webp)
FVR-C11S-EN
8-7
8 Maintenance and Inspection
8
2) Insulation test in the control circuit
The megger test and the dielectric strength test
must not be executed in the control circuit be-
cause those parts will be damaged and cannot
be repaired.
Use a high-resistance multimeter for the control
circuit.
1. Remove all external wiring from the control
circuit terminals.
2. Execute a continuity test between
grounds. If the result is 1M
Ω
or more, it is
normal.
3) External main circuit and sequence control
circuit
Remove wiring from all the terminals of the in-
verter in order not to apply the test voltage to
the inverter.
8-5 Parts Replacement
The life expectancy of a part depends on the
type of the part and the environment and the us-
age conditions. Parts should be replaced as
shown in Table 8-5-1.
For spare parts, please contact Fuji distributor.
Table 8-5-1
Parts replacement
8-6 Inquiries about the Product
and Guarantee of the product
1) For inquiries
If there is damage, a fault in the product, or a
question about the product, provide the following
information to your local distributor or nearest
Fuji’s sales office:
a) Inverter type
b) SER. No. (equipment serial number)
c) Purchasing date
d) Inquiry contents (e.g., damaged part and
the extent of damage, questions, phenom-
enon, and status of a fault)
2) Guarantee of the product
The product guarantee term is one year after
purchase or 18 months from the year and month
of manufacture on the nameplate, whichever ex-
pires first.
However, the product will not be repaired free of
charge in the following cases, even if the guar-
antee term has not expired:
1. The cause is incorrect use or inappropriate
repairing and modification.
2. The product is used outside the standard
specified range.
3. The cause is dropping after purchasing or
damage during transport.
4. The cause is earthquake, fire, storm or
flood damage, lightening, abnormal volt-
age, or other natural calamities and sec-
ondary disasters.
Part name
Standard
term for
replacement
Comments
Cooling fan
3 years
Exchange for a new
part
Smoothing
capacitor
5 years
Exchange for a new
part
(Decide after a
check)
Aluminum
electrolytic
capacitor
on the PC
board.
7 years
Exchange for a new
part
(Decide after a
check)
Other parts
-
Decide after a check