FVR-C11S-EN
5-14
5 Selecting Function
5
Change during operation: X = impossible,
= possible (enabled by using
),
= possible (enabled by using
)
DC injection brake (Braking time)
This function sets the DC injection braking time.
0.0
: No DC injection braking
0.1 to 30.0 : DC injection braking time 0.1 to 30s
(in 0.1s step)
Starting frequency
Stop frequency
These functions set a starting or stop frequency
in a range from 1 to 6Hz in 1Hz step.
Output frequency in forward/reverse operation
Starting frequency < stop frequency
If the set frequency is lower than the stop fre-
quency, the inverter output is 0Hz.
Factory setting
Change during
operation
0.0s
Factory
setting
Change during
operation
F23
1Hz
X
F25
1Hz
X
F22
Time
DC injection brake
Output voltage
Output Freq.
3Hz
CAUTION
Do not use the inverter brake function
for mechanical holding.
Otherwise injuries could occur.
F23
F25
1Hz
to
6Hz
1
6
0.2Hz
Starting frequency setting
Stop frequency setting
Stop frequency setting
Starting frequency setting
FWD
REV
Stop frequency setting
Starting frequency setting
t