6 Protective Function
6-3
FVR-C11S-EN
6
Figure. 6-2-1 How to input the reset command
6-2 Alarm Reset
To release the trip status, enter the reset command by pressing the re-
set key or from terminal (RST) after removing the cause of the trip.
Since the reset command is an edge operation, be sure to input a com-
mand string such as OFF
ON
OFF as shown in Figure 6-2-1.
When releasing the trip status, set the operation command to OFF.
When the operation command is set to ON, check that operation starts
after resetting.
If the cause of tripping is Er1, reset the error and initialize data. If the
inverter is not reset, contact Fuji Electric.
If alarm reset is activated with operation signal ON, the inverter sud-
denly restarts which may be hazardous. Be sure to disable the oper-
ating signal when releasing the trip status:
Otherwise fire could occur.
씯
씯
Reset command
Keypad panel
display
Alarm output
Normal display Alarm display Normal display
OFF
OFF
ON
OFF
OFF
ON
10ms or more
Trip