5-4
5 Selecting Function
FVR-C11S-EN
5
Change during operation: X = impossible,
= possible (enabled by using
),
= possible (enabled by using
)
C: Control Functions of Frequency
Func-
tion
code
No.
Name
Setting range
Unit
Min.
unit
Factory
setting
Change
during
opera-
tion
User
set-
ting
C01
Jump frequency1
0 to 120Hz
Hz
1
0
C02
2
1
0
C03
3
1
0
C04
(Hysteresis) 0 to 30Hz
Hz
1
3
C05
Multistep
frequency 1
0.0 to 120Hz
Hz
0.1
0.0
C06
2
0.1
0.0
C07
3
0.1
0.0
P: Motor Parameters
Func-
tion
code
No.
Name
Setting range
Unit
Min.
unit
Factory
setting
Change
during
opera-
tion
User
set-
ting
P00
Motor
characteristics
0 to 10
-
-
2
H: High Performance Functions
Func-
tion
code
No.
Name
Setting range
Unit
Min.
unit
Factory
setting
Change
during
opera-
tion
User
set-
ting
H01
Operation time
Operation time accumulation
100
Hr
1
0
-
H02
Trip history
The contents of the last four alarms are
displayed sequentially.
-
-
---
-
H03
Data
initialization
1: Initialized
(return to factory setting value)
-
-
0