9
EEPROM
Sensor
parameters
Analog to
Digital
Converter
Digital to Analog
Converter
Micro Processor
• Signal conditioning
• Reranging
• Diagnostics
• Communication
EEPROM
Transmitters
Parameters
Communication
FUJI/HART
®
Manual
Zero/Span
Adjustment
25.0
8.00 kPa
FXW
0 Y
1
4
7
8
9
6
5
2
3
M
N
O
S
R
Q
U
V
W
Z
.
[
HHC
Hand held Communicator
{
HP
LP
Control
system
Analog indicator
(option)
4-20 mA signal
LCD digital indicator
(option)
Micro
Capacitance
Silicon Sensor
Sensor Unit
Electronics Unit
1
The FCX-AII series transmitter accurately measures the differential pressure, level liquid, gauge
pressure or
fl
ow rate, and transmits a proportional current signal of 4 to 20mA DC.
All the adjustment functions are incorporated in the transmission unit for making adjustments
easily and exactly.
Transmitter settings (such as range and damping time constant, etc.) can be changed from an
FXW communicator (Hand Held Communicator).
The transmitter utilizes a unique micromachined capacitive silicon sensor with state-of-the-art
microprocessor technology to provide exceptional performance and functionnality.
The transmitter is compact and light, provide high accuracy and reliability.
Local adjustment of zero and span are possible from outside screw on the electronic housing.
Measuring principle
The operating principle of the FCX-AII series transmitter is shown in the block diagram below.
The input pressure is changed into an electrostatic capacitance in the detecting unit.
The change proportional to the pressure undergoes conditioning and ampli
fi
cation in the trans-
mission unit, and is then output as a current of 4 to 20mA DC
OUTLINE