23
The output mode is used to select the
proportional mode (proportional to input
differential pressure) or square root ex-
traction mode (proportinal to
fl
ow rate)
for output signal (4 to 20mA).
In case of square root extraction mode,
the cut point and the mode below the cut
point can be set.
Under display 2 , press <INC> or <DEC>
for selection of the square root extraction
mode or proportional mode.
Change of output mode
<INC> <DEC>
a:
OUT=LIN
b:
OUT=SQR
Since display 7 is presented when the
square root extraction mode is selected,
the low
fl
ow cut point should be set.
Cut point is adjustable within the range
of 0.00 to 20.00%. The cut point is used
for stabilizing output near 0% when the
square root extraction mode is selected
for output signal.
There are two modes; in one mode,
proportional output is selected for output
below a cut point (Fig. A) and in the other
mode, out put is forcibly reduced to 0%
for output below a cut point (Fig. B).
Under display 13 , linear or zero output
is selectable for output below the cut
point.
Output Mode
8:
OUTPUT MODE
XMTR:DP
OUT=LIN
< INC > < CHANGE >
8-1: MODE CHANGE
XMTR : DP
OUT=LIN
< INC > < ENT > < CL >
8-1: MODE CHANGE
XMTR : GP
OUT=LIN
< ENT > < CL >
8-1:
MODE CHANGE
XMTR:DP
OUT=SQR
CHNG OK? < ENT/CL >
8
: OUTPUT MODE
XMTR:GP
OUT=LIN
< INC > < CHANGE >
8-2: MODE WRITE
XMTR:DP
OUT=SQR
8-3: LOW CUT
POINT=
ss
.
ss
%FLOW
MODE=
oooooo
< CHANGE > < CL >
< ENT > < CL >
8-5:
POINT WRITE
ss
.
ss
%FLOW
8-7: LOW CUT MODE
< 1 > LINEAR
< 2 > ZERO
< 1 > < 2 > <CL >
8-7: MODE CHANGE
LINEAR
CHNG OK? < ENT/CL >
8-8: MODE WRITE
LINEAR
8-1: MODE
CHANGE
XMTR:DP
OUT=LIN
CHNG OK? < ENT/CL >
*1
<OUTPUT MODE
CHANGE>
8-4:
POINT CHANGE
ss
.
ss
%FLOW
8-4: POINT CHANGE
ss
.
ss
%FLOW
8-6:
LOW CUT MODE
ZERO
< CHANGE > < CL >
8-7:
MODE CHANGE
ZERO
CHNG OK? < ENT/CL >
8-8:
MODE WRITE
ZERO
OUT=LIN
LIN/
D
8-2:
MODE WRITE
XMTR:DP
OUT=LIN
INC
1
1
INC
(a)
(DP)
GP, AP, LL (Liquid Level)
2
CL
ENT
ENT
5
CL
ENT
3
CL
CL
4
ENT
6
CHNG
CL
CHNG
CHNG
7
ENT
CL
ENT
CL
CL
8
1
OUT=SQR
2
9
CHNG
10
8-6:
LOW CUT MODE
LINEAR
< CHANGE > < CL >
11
CL
12
CL
16
ENT
13
CL
2
1
ENT
CL
14
15
17
< INC >
*1
*2 0.00% Cut Point 20.00% FLOW
Note) GP, AP, LL : OUT = LIN only
< DEC > Available Mode
In case of OUT= SQR
In case of OUT=LIN
CHNG
Menu No.9
(a)
*2
CHNG OK? < ENT/CL >
oooooo
= LINEAR or ZERO
Output
Output
Differential
input
Differential
input
Fig. A: With linear output
selected in low cut mode
Fig. B: With zero output
selected in low cut mode