M6500 Series NE Configuration Manual
103
Figure5-79 Create Two-way Cross-Connection of ODU4
Build the environment according to the following diagram.
Respectively create the two-way SNC cross-connection with protection of port1 to port3 (primary)/port3
(standby) at Site A and Site C.
Ensure that the client side service types including mapping methods of Site A and Site C are the same.
Create two-way cross-connection for ODU4 of port3 to port3 at Site B. Site B acts as the transparent
transmission site.