M6500 Series NE Configuration Manual
106
value expected to be received at the opposite end. That is to say, the two network elements connected by the
overhead should meet the rules as shown in table 6-1
:
Table6-1 Overhead Establishment Rules
NE A
Set Relationship
NE B
Send TTI
SAPI
=
SAPI
Receive TTI
DAPI
=
DAPI
Receive TTI
SAPI
=
SAPI
Send TTI
DAPI
=
DAPI
6.2. Configuration Steps
6.2.1. SM Configuration Steps
Here we take M6500-MXP10 board as an example to introduce the SM configuration steps:
Activate the connection and monitoring enablement of SM overhead.
In M Series NMS, the service XGE_GFPF is configured for port 1 of the local end and opposite end of
M6500-MXP10 board (Specific service is configured according to actual demand). OTU4 service is configured for
port 11 of the local-end and opposite-end board (Specific service is configured according to actual demand).
Demultiplex ODU4 to ODU2, configure service cross-connection, connect optical fiber and build the
environment.
Configuration Steps
Click on port 11 at the local end to enter the port management interface of the local end. Click on and
enter“
OTU4
”option interface, then set“
Path Trace Mismatch (TIM) Mode
” as“
Source & Destination Access
Identifier
”(SAPI&DAPI), and set the status of“
Path Trace Mismatch (TIM) Affects Service
”as“
Yes
”. The opposite-end
SM overhead configuration method is the same as that of the local end, we will not go into much detail here.
Figure6-1 Enter Port Management Interface
Содержание M6500 Series
Страница 12: ...M6500 Series NE Configuration Manual 11 Figure 1 3 Start NMS Server...
Страница 63: ...M6500 Series NE Configuration Manual 62 Figure 4 34 Parameter Reading of WDM CFP2 Optical Transceiver...
Страница 105: ...M6500 Series NE Configuration Manual 104 Figure5 80 Site to Site Primary and Standby Protection Environment...
Страница 109: ...M6500 Series NE Configuration Manual 108 Figure6 5 TP Multiplexing Configuration Step 2...
Страница 113: ...M6500 Series NE Configuration Manual 112 Figure6 12 Set Line Side PM Overhead...
Страница 116: ...M6500 Series NE Configuration Manual 115 Figure6 16 Configure Line Side Port TTI...
Страница 117: ...M6500 Series NE Configuration Manual 116 Figure6 17 Configure Client Side Local End Port TTI...
Страница 118: ...M6500 Series NE Configuration Manual 117 Figure6 18 Configure Client Side Opposite End Port TTI...
Страница 129: ...M6500 Series NE Configuration Manual 128 Figure7 10 Select Protection Mode...
Страница 138: ...M6500 Series NE Configuration Manual 137 Figure8 14 Alarm Details Figure8 15 Alarm Document Link...