M6500 Series NE Configuration Manual
180
Figure9-91 Successfully Export Data of SDH Regeneration Segment
9.3.6. History Performance Statistics of Ethernet
9.3.6.1. Ethernet History Monitoring Parameters Introduction
The monitoring parameter of the history monitoring point for Ethernet includes time interval, which is a
shortcut to choose the time. There are three options--one day, three days and a week for you to choose.
Duration: You can choose a specific day or a period of time according to your needs.
Performance Monitoring Point: entrance-near end, exit-near end.
Performance Monitoring Parameters: The monitoring parameters of Ethernet monitoring point include normal
frame number, unicast frame number, multicast frame number, broadcast frame number, CRC error frame,
alignment error frame number, ultra long frame number (Frame Too Long), ultra long Jabber frame number
(CRC error), ultra short frame number (CRC error), discarded frame number, ultra short frame number (CRC
normal), 64-byte frame number, 65-127-byte frame number, 128-255-byte frame number, 256-511-byte frame
number, 512-1023-byte frame number, 1024-1518-byte frame number.
Figure9-92 Ethernet History Performance Parameters
9.3.6.2. View Ethernet History Monitoring Information
15minutes and 24hours of Ethernet history data operation and display are the same form. Here we take
15-minute Ethernet history monitoring point as an example. Choose the appropriate network elements, slots,
ports and monitoring cycles through the screening box above the menu, and then select the time interval,
performance monitoring point and parameters which need to be monitored in the right menu.Parameters to be
monitored can be all selected or only select one or two of them to check.After that, click Apply button on the
lower right corner. From the graph, we can see the trend of the refraction chart of the monitoring parameters.
Содержание M6500 Series
Страница 12: ...M6500 Series NE Configuration Manual 11 Figure 1 3 Start NMS Server...
Страница 63: ...M6500 Series NE Configuration Manual 62 Figure 4 34 Parameter Reading of WDM CFP2 Optical Transceiver...
Страница 105: ...M6500 Series NE Configuration Manual 104 Figure5 80 Site to Site Primary and Standby Protection Environment...
Страница 109: ...M6500 Series NE Configuration Manual 108 Figure6 5 TP Multiplexing Configuration Step 2...
Страница 113: ...M6500 Series NE Configuration Manual 112 Figure6 12 Set Line Side PM Overhead...
Страница 116: ...M6500 Series NE Configuration Manual 115 Figure6 16 Configure Line Side Port TTI...
Страница 117: ...M6500 Series NE Configuration Manual 116 Figure6 17 Configure Client Side Local End Port TTI...
Страница 118: ...M6500 Series NE Configuration Manual 117 Figure6 18 Configure Client Side Opposite End Port TTI...
Страница 129: ...M6500 Series NE Configuration Manual 128 Figure7 10 Select Protection Mode...
Страница 138: ...M6500 Series NE Configuration Manual 137 Figure8 14 Alarm Details Figure8 15 Alarm Document Link...