M6500 Series NE Configuration Manual
56
M6500-MXP10
1*100G line side interface (CFP)
10
*
10G client side interface
(SFP+)
The client side signal (10GE, STM-64/OC-192) is mapped
to ODU2/2e.
The line side signal is demultiplexed from ODU4 to
ODU2/2e and connected to the client side signal.
100G line side supports G.709 general FEC or
Soft-Decision FEC.
10G OTU2/2e supports I.4 and I.7 EFEC, or G.709 general
FEC
Support GCC0, GCC1 and GCC2 in-band management
Support SNC/I and SNC/N transmission protection
M6500-TMXP2
1*100G line side interface (CFP)
1*100G (QSFP28) or 2*40G
client side interface (QSFP+)
The client side 100G signal (100GE or OTU4) is mapped
to ODU4.
The client side 40G signal (40GE or OTU3) is mapped to
ODU3.
The line side signal is terminated to ODU4 or ODU3, and
is connected to the client side signal.
100G line side supports G.709 general FEC or
Soft-Decision FEC
Support GCC0, GCC1 and GCC2 in-band management
Support SNC/I and SNC/N transmission protection
M6500-TMXP5
1*100G/200G line side interface
(CFP2)
2*100G (QSFP28) or 4*40G
client side interface (QSFP+) or
20* (4x5) 10G client side
interface
The client side 100G signal (100GE or OTU4) is mapped
to ODU4
The client side 40G signal (40GE or OTU3) is mapped to
ODU3.
The client side 10G signal (10GE, STM-64/OC-192) is
mapped to ODU2/2e
The 100G signal on the line side is demultiplexed by
ODU4 to ODU2/2e or ODU3, and is connected to the
client side signal
The 200G signal on the line side is demultiplexed from
ODUC2 to ODU4, and then demultiplexed to low-order
ODU2/2e or ODU3, which is connected to the client side
signal
100G line side supports G.709 general FEC or
Soft-Decision FEC
200G line side supports Soft-Decision FEC
10G OTU2/2e supports I.4 and I.7 EFEC, or G.709 general
FEC
Support GCC0, GCC1, GCC2, GCC1+2 in-band
management
4.5. Configuration of Optical Module Information
The operation steps to view optical module information are as follows:
Select NE-Slot1, click on “
Port
”and select “
Pluggable
Configuration
”on the right, as shown in the figure below:
Содержание M6500 Series
Страница 12: ...M6500 Series NE Configuration Manual 11 Figure 1 3 Start NMS Server...
Страница 63: ...M6500 Series NE Configuration Manual 62 Figure 4 34 Parameter Reading of WDM CFP2 Optical Transceiver...
Страница 105: ...M6500 Series NE Configuration Manual 104 Figure5 80 Site to Site Primary and Standby Protection Environment...
Страница 109: ...M6500 Series NE Configuration Manual 108 Figure6 5 TP Multiplexing Configuration Step 2...
Страница 113: ...M6500 Series NE Configuration Manual 112 Figure6 12 Set Line Side PM Overhead...
Страница 116: ...M6500 Series NE Configuration Manual 115 Figure6 16 Configure Line Side Port TTI...
Страница 117: ...M6500 Series NE Configuration Manual 116 Figure6 17 Configure Client Side Local End Port TTI...
Страница 118: ...M6500 Series NE Configuration Manual 117 Figure6 18 Configure Client Side Opposite End Port TTI...
Страница 129: ...M6500 Series NE Configuration Manual 128 Figure7 10 Select Protection Mode...
Страница 138: ...M6500 Series NE Configuration Manual 137 Figure8 14 Alarm Details Figure8 15 Alarm Document Link...