M6500 Series NE Configuration Manual
44
Table4-3 LED Indicator Status of System Board Optical Management Port
M6500-CH5U
M6500-CH2U
System Board
Optical Management
Port
(MGMT) LED Indicator
Monochromatic
Green Light
Off: The port is disabled/
There is los alarm.
Green Light On: There is
no los alarm and the
port is enabled.
Off: The port is
disabled/There is los alarm.
Green Light On: There is no
los alarm and the port is
enabled.
4.2.2. System Interface LED Indicator
Table4-4 System Interface LED Indicator Status
M6500-CH5U
M6500-CH2U
System Interface
LED Indicator
SYS
Located in Fan Tray: Green Light
On: The system is successfully
started.
Green Light Off: The system is not
started.
On NMU Board:
Green Light On: The system is
successfully started.
Green Light Off: The system is not
started.
CR/MJ/MN
Located in Fan Tray:
CR: Red Light On: There is Critical
alarm.
MJ: Orange Light On: There is
Major alarm.
MN: Yellow Light On: There is
Minor alarm.
On NMU Board:
CR: Red Light On: There is Critical
alarm.
MJ: Orange Light On: There is
Major alarm.
MN: Yellow Light On: There is
Minor alarm.
4.2.3. Service Board LED Indicator
Table4-5 Service Board LED Indicator Status
M6500-CH5U
M6500-CH2U
Service Board
LED Indicator
RUN
Green Light Slow Flash: The
software is started.
Green Light Off: The
software is not started.
Green Light Slow Flash: The software is
successfully started and it is active
board.
Green Light On: The software is
successfully started but it is standby
board.
Green Light Off: The software is not
started.
FAULT/ALM
Red Light Quick Blink: The
board is mismatched.
Red Light Slow Flash: There
is latch-open alarm.
Red Light On: There is
alarm.
Red Light Off: There is no
alarm.
Red Light Quick Blink: The board is
mismatched.
Red Light Slow Flash: There is latch-open
alarm.
Red Light On: There is alarm.
Red Light Off: There is no alarm.
Содержание M6500 Series
Страница 12: ...M6500 Series NE Configuration Manual 11 Figure 1 3 Start NMS Server...
Страница 63: ...M6500 Series NE Configuration Manual 62 Figure 4 34 Parameter Reading of WDM CFP2 Optical Transceiver...
Страница 105: ...M6500 Series NE Configuration Manual 104 Figure5 80 Site to Site Primary and Standby Protection Environment...
Страница 109: ...M6500 Series NE Configuration Manual 108 Figure6 5 TP Multiplexing Configuration Step 2...
Страница 113: ...M6500 Series NE Configuration Manual 112 Figure6 12 Set Line Side PM Overhead...
Страница 116: ...M6500 Series NE Configuration Manual 115 Figure6 16 Configure Line Side Port TTI...
Страница 117: ...M6500 Series NE Configuration Manual 116 Figure6 17 Configure Client Side Local End Port TTI...
Страница 118: ...M6500 Series NE Configuration Manual 117 Figure6 18 Configure Client Side Opposite End Port TTI...
Страница 129: ...M6500 Series NE Configuration Manual 128 Figure7 10 Select Protection Mode...
Страница 138: ...M6500 Series NE Configuration Manual 137 Figure8 14 Alarm Details Figure8 15 Alarm Document Link...