M6500 Series NE Configuration Manual
129
7.
Select client side port number and line side port number. The tag name can be empty. Create the
cross-connection of SNC protection service, then click on“
PPG
”option of the created SNC cross-connection with
protection.
Figure7-11 Click Protection Group
Select the protection type--“
SNC/I
”or“
SNC/N
”.
Figure7-12 Select Protection Type
8.
Reply wait settings—select“
Revertive
”or“
Non Revertive
”. If“
Revertive
”mode is selected, the reply waiting
time needs to be entered.