3
Open the access point by touching the sensor once → Communication LED:
flashes blue.
4
Follow and complete the installation wizard in the individual sections.
5
Add system components in Solar.web and start up the PV system.
The network wizard and the product setup can be carried out independently of each oth-
er. A network connection is required for the Solar.web installation wizard.
Installation using
the web browser
WLAN:
1
Open the access point by touching the sensor once → Communication LED:
flashes blue.
2
Establish the connection to the inverter in the network settings (the inverter is dis-
played with the name "FRONIUS_PILOT" and the serial number of the device).
3
Password: enter 12345678 and confirm.
IMPORTANT!
To enter the password on a Windows 10 operating system, the link "Connect using a
security key instead" must first be activated to establish a connection with the pass-
word: 12345678.
4
In the browser address bar, enter and confirm the IP address 192.168.250.181. The
installation wizard is opened.
5
Follow the installation wizard in the individual sections and complete the installation.
6
Add system components in Solar.web and start up the PV system.
The network wizard and the product setup can be carried out independently of each oth-
er. A network connection is required for the Solar.web installation wizard.
Ethernet:
1
Establish a connection to the inverter (LAN1) with a network cable (CAT5 STP or
higher).
2
Open the access point by touching the sensor once → Communication LED:
flashes blue.
3
In the browser address bar, enter and confirm IP address 169.254.0.180. The install-
ation wizard is opened.
4
Follow the installation wizard in the individual sections and complete the installation.
5
Add system components in Solar.web and start up the PV system.
The network wizard and the product setup can be carried out independently of each oth-
er. A network connection is required for the Solar.web installation wizard.
75
EN
Содержание Symo GEN24 3.0
Страница 2: ......
Страница 11: ...General information 11...
Страница 12: ...12...
Страница 31: ...Backup power variant PV Point OP 31...
Страница 32: ...32...
Страница 34: ...34...
Страница 35: ...Installation 35...
Страница 36: ...36...
Страница 77: ...Settings website of the inverter 77...
Страница 78: ...78...
Страница 104: ...104...
Страница 105: ...Options 105...
Страница 106: ...106...
Страница 115: ...2 Set the DC disconnector to the On switch position Switch on the automatic circuit breaker 115 EN...
Страница 116: ...116...
Страница 117: ...Appendix 117...
Страница 118: ...118...
Страница 132: ...132...
Страница 133: ...Circuit diagrams 133...
Страница 134: ...134...
Страница 135: ...Circuit Diagram PV Point OP Circuit Diagram 135 EN...
Страница 136: ...Fronius Symo GEN24 and BYD Battery Box Premi um HV Circuit Diagram 136...
Страница 137: ...Wiring diagram surge protective device SPD Circuit Diagram 137 EN...
Страница 138: ...138...
Страница 139: ...Dimensions of the inverter 139...
Страница 140: ...140...
Страница 141: ...Fronius Symo GEN24 3 5 kW Fronius Symo GEN24 3 5 kW 141 EN...
Страница 142: ...142...
Страница 143: ...143 EN...
Страница 144: ......