Fronius Symo GEN24
Device concept
The inverter transforms the direct current generated by the solar modules into alternating
current. This alternating current is fed into the public grid and synchronized with the grid
voltage in use. Moreover, the solar energy can also be stored in a connected battery for
later use.
The inverter is intended for use in grid-connected photovoltaic systems. The inverter has
a backup power function and switches to backup power mode if it has been wired ac-
cordingly*.
The inverter automatically monitors the public grid. Whenever conditions in the electric
grid are inconsistent with standard conditions (for example, grid switch-off, interruption),
the inverter will immediately stop producing power and interrupt the supply of power into
the grid.
The grid is monitored by monitoring the voltage, frequency and islanding conditions.
After installation and commissioning, the inverter's operation is fully automatic;
the inverter draws the maximum possible power from the PV modules.
Depending on the operating point, this power is used in the home, stored in a battery* or
fed into the grid.
As soon as the energy provided by the PV modules is no longer sufficient, the power
from the battery is fed into the home. Depending on the setting, power may also be ob-
tained from the public grid in order to charge the battery*.
When its temperature gets too high, the inverter automatically reduces the output or
charging power, or switches off completely, in order to protect itself.
Reasons for the temperature being too high include a high ambient temperature or insuf-
ficient heat dissipation (for example, inadequate heat dissipation when installed in switch
cabinets).
*
Depending on the device variant, suitable battery, appropriate wiring, settings
and local standards and guidelines.
Function over-
view
Function
Symo GEN24
Symo GEN24 Plus
Backup power variant - PV Point (OP)
Battery connection*
Available as an op-
tion**
Backup power variant - Full Backup
*
For suitable batteries, see chapter
**
The functions are optionally available via Fronius UP (see chapter
).
Fronius UP
With Fronius UP*, the inverter can be expanded by the authorised specialist to include
optionally available functions (see chapter
*
The availability of Fronius UP varies from country to country. For more informa-
tion on Fronius UP and availability, see
Installation guide: Fronius GEN24 &
13
EN
Содержание Symo GEN24 3.0
Страница 2: ......
Страница 11: ...General information 11...
Страница 12: ...12...
Страница 31: ...Backup power variant PV Point OP 31...
Страница 32: ...32...
Страница 34: ...34...
Страница 35: ...Installation 35...
Страница 36: ...36...
Страница 77: ...Settings website of the inverter 77...
Страница 78: ...78...
Страница 104: ...104...
Страница 105: ...Options 105...
Страница 106: ...106...
Страница 115: ...2 Set the DC disconnector to the On switch position Switch on the automatic circuit breaker 115 EN...
Страница 116: ...116...
Страница 117: ...Appendix 117...
Страница 118: ...118...
Страница 132: ...132...
Страница 133: ...Circuit diagrams 133...
Страница 134: ...134...
Страница 135: ...Circuit Diagram PV Point OP Circuit Diagram 135 EN...
Страница 136: ...Fronius Symo GEN24 and BYD Battery Box Premi um HV Circuit Diagram 136...
Страница 137: ...Wiring diagram surge protective device SPD Circuit Diagram 137 EN...
Страница 138: ...138...
Страница 139: ...Dimensions of the inverter 139...
Страница 140: ...140...
Страница 141: ...Fronius Symo GEN24 3 5 kW Fronius Symo GEN24 3 5 kW 141 EN...
Страница 142: ...142...
Страница 143: ...143 EN...
Страница 144: ......