
IMPORTANT!
The inverter must not be installed or used at altitudes above 4000 m.
Do not install the inverter in:
-
Areas where it may be exposed to ammonia, corrosive gases,
acids or salts (e.g. fertiliser storage areas, vent openings for live-
stock stables, chemical plants, tanneries, etc.)
During certain operating phases the inverter may produce a slight
noise. For this reason it should not be installed in an occupied living
area.
Do not install the inverter in:
-
Areas where there is an increased risk of accidents from farm an-
imals (horses, cattle, sheep, pigs, etc.)
-
Stables or adjoining areas
-
Storage areas for hay, straw, chaff, animal feed, fertilizers, etc.
The inverter is essentially designed to be dustproof (IP 66). In areas of
high dust accumulation, dust deposits may collect on the cooling sur-
faces, and thus impair the thermal performance. Regular cleaning is
required in this case, see chapter
Operation in dusty environments
on page
. We therefore recommend not installing the inverter in
areas and environments with high dust accumulation.
Do not install the inverter in:
-
Greenhouses
-
Storage or processing areas for fruit, vegetables or viticulture
products
-
Areas used in the preparation of grain, green fodder or animal
feeds
Choosing the loc-
ation of third-
party batteries
IMPORTANT!
Refer to the manufacturer's documents for the suitable location for third-party batteries.
Explanation of
symbols for the
installation posi-
tion
The inverter is suitable for vertical installation on a vertical wall or
column.
40
Содержание Symo GEN24 3.0
Страница 2: ......
Страница 11: ...General information 11...
Страница 12: ...12...
Страница 31: ...Backup power variant PV Point OP 31...
Страница 32: ...32...
Страница 34: ...34...
Страница 35: ...Installation 35...
Страница 36: ...36...
Страница 77: ...Settings website of the inverter 77...
Страница 78: ...78...
Страница 104: ...104...
Страница 105: ...Options 105...
Страница 106: ...106...
Страница 115: ...2 Set the DC disconnector to the On switch position Switch on the automatic circuit breaker 115 EN...
Страница 116: ...116...
Страница 117: ...Appendix 117...
Страница 118: ...118...
Страница 132: ...132...
Страница 133: ...Circuit diagrams 133...
Страница 134: ...134...
Страница 135: ...Circuit Diagram PV Point OP Circuit Diagram 135 EN...
Страница 136: ...Fronius Symo GEN24 and BYD Battery Box Premi um HV Circuit Diagram 136...
Страница 137: ...Wiring diagram surge protective device SPD Circuit Diagram 137 EN...
Страница 138: ...138...
Страница 139: ...Dimensions of the inverter 139...
Страница 140: ...140...
Страница 141: ...Fronius Symo GEN24 3 5 kW Fronius Symo GEN24 3 5 kW 141 EN...
Страница 142: ...142...
Страница 143: ...143 EN...
Страница 144: ......