Troubleshooting
PROBLEM
CAUSE
SOLUTION
The machine does not start (All the LEDs of the
keys are off).
Master switch open.
Close the switch.
Incorrect power supply.
Check power supply.
Electrical anomaly.
Contact the technician
1
.
The compressor functions intermittently from the
first batch freezing phases.
Air
-
cooled machines: air condenser dirty or fan
faulty.
Clean the condenser with a brush and make sure the
fan works properly.
Water
-
cooled machines: no condensation water.
Make sure there is water in the water system to
which the machine is connected. Check the cocks.
The batch freezing times lengthen and/or the ice
-
cream appears wet.
Slight condensation.
Check the installation conditions Chap.II/3
High room temperature.
Check that the room temperature does not exceed
32°C (90°F).
High liquid mixture temperature.
Maximum machine production is obtained with a
liquid mixture at 4°C (39°F). Using mixtures at higher
temperatures means that batch freezing times are
lengthened: this is normal and does not constitute an
anomaly.
Worn scrapers.
Check wear and replace them if necessary.
Refrigeration system anomaly.
Contact the technician
1
.
Unbalanced mixture or incorrect amount introdu-
ced.
Check that the amount of mixture introduced is cor-
rect and that it is properly balanced.
The product is too soft.
The selected working program is incorrect.
Select a program higher number
The product is too hard.
The selected working program is incorrect..
Select a program lower number.
The machine becomes noisy during batch
freezing.
Check the wear of the scraper.
Make sure the mix is properly balanced.
Check that the beater rotates counterclockwise.
Otherwise, turn off the machine and contact your
service technician
1
.
Ensure that the amount present in the cylinder is not
lower than the minimum allowed.
1
= These operations are reserved exclusively for authorised from the manifacturer and qualified personnel.The list of authorized technical assistance cen-
ters is available on the site: www.frigomat.com/en/partners/world.
The manufacturer declines all and any liability for damage caused by failure to comply with the above indications.
Presence of ice on the cylinder wall.
Содержание GX2
Страница 10: ...FRIGOMAT GX2 GX4 9 IT ...
Страница 28: ...EN FRIGOMAT GX2 GX4 9 ...
Страница 46: ...FRIGOMAT GX2 GX4 9 FR ...
Страница 56: ...FRIGOMAT GX2 GX4 19 EN IT FR DE ES CZ PL ...
Страница 74: ...FRIGOMAT GX2 GX4 xviii EN IT FR DE ES CZ PL ...
Страница 75: ...FRIGOMAT GX2 GX4 xix EN IT FR DE ES CZ PL ...
Страница 76: ...FRIGOMAT GX2 GX4 xx EN IT FR DE ES CZ PL ...