The cart comprises 4 wheels. The two wheels on the front (A) are each
equipped with a break. The device can be swiveled, turned, or moved
in any direction by means of the two handles on the upper part (monitor
hood).
Locking
All breaks must be locked if the device is in its final position or in
operation.
Relocation inside buildings during preparation (recirculation)
Before relocating
After the device has been set up, it may only be relocated inside a
building or ward.
In other words:
– The functional test is complete.
– The tubing systems (cassette) have been inserted, primed, and
rinsed.
– The treatment parameters have been entered.
– The device is in the "Recirculation" mode.
– The loads on the device must not exceed the following
specifications. Preferably use the front hooks.
The device can be disconnected from the power supply by pulling out
the power plug. The device indicates a power failure. The audible alarm
can be suppressed for 2 minutes by pressing the
[Mute]
key. The
device must be relocated as fast as possible, as battery operation is
only possible for a limited time.
A
Left IV pole
5 kg
Substituate / dialysate scale, each
12 kg
Right IV pole
6 kg
Содержание multiFiltrate
Страница 1: ...multiFiltrate Instructions for Use Software version 5 3 Edition 15A 2015 Part no M56 963 1 ...
Страница 2: ......
Страница 11: ...Fresenius Medical Care multiFiltrate IFU EN UK 15A 2015 xi 15 2 Instructions on the use of free software 15 2 ...
Страница 12: ...xii Fresenius Medical Care multiFiltrate IFU EN UK 15A 2015 ...
Страница 16: ...Chapter 1 Index 1 4 Fresenius Medical Care multiFiltrate IFU EN UK 15A 2015 ...
Страница 42: ...Chapter 3 Design 3 10 Fresenius Medical Care multiFiltrate IFU EN UK 15A 2015 ...
Страница 166: ...Chapter 4 Operation 4 124 Fresenius Medical Care multiFiltrate IFU EN UK 15A 2015 Interrupting the treatment ...
Страница 186: ...Chapter 5 Alarm processing 5 20 Fresenius Medical Care multiFiltrate IFU EN UK 15A 2015 ...
Страница 188: ...Chapter 6 Cleaning disinfection 6 2 Fresenius Medical Care multiFiltrate IFU EN UK 15A 2015 ...
Страница 218: ...Chapter 7 Functional description 7 30 Fresenius Medical Care multiFiltrate IFU EN UK 15A 2015 ...
Страница 228: ...Chapter 9 Installation 9 4 Fresenius Medical Care multiFiltrate IFU EN UK 15A 2015 ...
Страница 234: ...Chapter 11 Technical Safety Checks maintenance procedures 11 2 Fresenius Medical Care multiFiltrate IFU EN UK 15A 2015 ...
Страница 252: ...Chapter 12 Specifications 12 18 Fresenius Medical Care multiFiltrate IFU EN UK 15A 2015 ...
Страница 260: ...Chapter 13 Definitions 13 8 Fresenius Medical Care multiFiltrate IFU EN UK 15A 2015 ...
Страница 266: ...Chapter 14 Options 14 6 Fresenius Medical Care multiFiltrate IFU EN UK 15A 2015 ...
Страница 282: ...Chapter 15 Appendix 15 16 Fresenius Medical Care multiFiltrate IFU EN UK 15A 2015 ...