Chapter 4: Operation
Fresenius Medical Care multiFiltrate IFU-EN-UK 15A-2015
4-107
Treatment menu
4.11.3 Substituate / dialysate / filtrate bag change
4.11.4 Ci-Ca bag change
Note
The bag change menu can be accessed:
– Manually by selecting the
Change bag
menu.
– Automatically after a bag change notification.
– Automatically after changing the procedure.
– Automatically after selecting or deselecting Ci-Ca anticoagulation.
The following information will be displayed:
The current weight on the active scale
and the required HF solution.
"Not active"
(red) the deactivated
scales.
The current weight on the filtrate scales.
Place the solution bag in question on the
scales or replace it, and / or empty the
filtrate bag.
In the event of presence of air in one of the
tubing systems, disconnect the
corresponding outlet.
Use the rotary selector to select
Deaeration XXX
, and press and hold
[OK]
until all air has been removed from
the tubing system. Reconnect the
deaerated tubing system.
Use the rotary selector to select
Terminate bag change? [OK] to
confirm!
from the menu field and press
[OK]
.
Note
The Ci-Ca bag change menu can be accessed:
– Manually by selecting the
Ci-Ca bag change
menu.
– Automatically after a bag change notification.
Содержание multiFiltrate
Страница 1: ...multiFiltrate Instructions for Use Software version 5 3 Edition 15A 2015 Part no M56 963 1 ...
Страница 2: ......
Страница 11: ...Fresenius Medical Care multiFiltrate IFU EN UK 15A 2015 xi 15 2 Instructions on the use of free software 15 2 ...
Страница 12: ...xii Fresenius Medical Care multiFiltrate IFU EN UK 15A 2015 ...
Страница 16: ...Chapter 1 Index 1 4 Fresenius Medical Care multiFiltrate IFU EN UK 15A 2015 ...
Страница 42: ...Chapter 3 Design 3 10 Fresenius Medical Care multiFiltrate IFU EN UK 15A 2015 ...
Страница 166: ...Chapter 4 Operation 4 124 Fresenius Medical Care multiFiltrate IFU EN UK 15A 2015 Interrupting the treatment ...
Страница 186: ...Chapter 5 Alarm processing 5 20 Fresenius Medical Care multiFiltrate IFU EN UK 15A 2015 ...
Страница 188: ...Chapter 6 Cleaning disinfection 6 2 Fresenius Medical Care multiFiltrate IFU EN UK 15A 2015 ...
Страница 218: ...Chapter 7 Functional description 7 30 Fresenius Medical Care multiFiltrate IFU EN UK 15A 2015 ...
Страница 228: ...Chapter 9 Installation 9 4 Fresenius Medical Care multiFiltrate IFU EN UK 15A 2015 ...
Страница 234: ...Chapter 11 Technical Safety Checks maintenance procedures 11 2 Fresenius Medical Care multiFiltrate IFU EN UK 15A 2015 ...
Страница 252: ...Chapter 12 Specifications 12 18 Fresenius Medical Care multiFiltrate IFU EN UK 15A 2015 ...
Страница 260: ...Chapter 13 Definitions 13 8 Fresenius Medical Care multiFiltrate IFU EN UK 15A 2015 ...
Страница 266: ...Chapter 14 Options 14 6 Fresenius Medical Care multiFiltrate IFU EN UK 15A 2015 ...
Страница 282: ...Chapter 15 Appendix 15 16 Fresenius Medical Care multiFiltrate IFU EN UK 15A 2015 ...