![Freescale Semiconductor MCF52230 ColdFire Скачать руководство пользователя страница 332](http://html1.mh-extra.com/html/freescale-semiconductor/mcf52230-coldfire/mcf52230-coldfire_reference-manual_2330648332.webp)
Ethernet Physical Transceiver (EPHY)
MCF52235 ColdFire® Integrated Microcontroller Reference Manual, Rev. 6
Freescale Semiconductor
19-11
19.3.3.2
Status Register
This register advertises the capabilities of the port to the MII.
Figure 19-7. Status Register
MII Register Address: 0x01
Access: User read/write
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
R
100
T4
100X
FD
100X
HD
10T
FD
10THD
0
0
0
0
SUP
PRE
AN
COMP
REM
FLT
AN
ABL
LNK
STST
JAB
DT
EX
CAP
W
Reset
0
1
1
1
1
0
0
0
0
1
0
0
1
0
0
1
Table 19-7. Status Register Field Descriptions
Field
Description
15
100T4
100BASE-T4
1 Indicates PHY supports 100BASE-T4 transmission
0 Indicates the PHY does not support 100BASE-T4 transmission
Note: This function is not implemented in the EPHY module.
14
100XFD
100BASE-TX Full-Duplex
1 Indicates PHY supports 100BASE-TX full-duplex mode
0 Indicates PHY does not support 100BASE-TX full-duplex mode
13
100XHD
100BASE-TX Half-Duplex
1 Indicates the PHY supports 100BASE-TX half-duplex mode
0 Indicates the PHY does not support 100BASE-TX half-duplex mode
12
10TFD
10BASE-T Full-Duplex
1 Indicates the PHY supports 10BASE-T full-duplex mode
0 Indicates the PHY does not support 10BASE-T full-duplex mode
11
10THD
10BASE-T Half-Duplex
1 Indicates the PHY supports 10BASE-T half-duplex mode
0 Indicates the PHY does not support 10BASE-T half-duplex mode
10–7
Reserved, should be cleared.
6
SUPPRE
MF Preamble Suppression
1 Indicates that management frames are not required to contain the preamble stream
0 Indicates that management frames are required to contain the preamble stream
5
ANCOMP
Auto-Negotiation Complete bit. To inform the management interface (MI) that it has completed
processing, ANCOMP is set by the A/N process. After it has been started, the auto-negotiation
process uses link code words to exchange capability information and establish the highest common
denominator (HCD) for link transactions.
1 Indicates that the auto-negotiation process has completed and that the contents of registers 4
through 7 are valid.
0 Indicates that the auto-negotiation process has not completed and that the contents of registers 4
through 7 are not valid
Because
of
an
order
from
the
United
States
International
Trade
Commission,
BGA-packaged
product
lines
and
part
numbers
indicated
here
currently
are
not
available
from
Freescale
for
import
or
sale
in
the
United
States
prior
to
September
2010:MCF52234CVM60,
MCF52235CVM60