Real-Time Clock
MCF52235 ColdFire® Integrated Microcontroller Reference Manual, Rev. 6
Freescale Semiconductor
8-8
8.2.7
RTC Interrupt Enable Register (RTCIENR)
The real-time clock interrupt enable register (RTCIENR) is used to enable/disable the various real-time
clock interrupts. Masking an interrupt bit has no effect on its corresponding status bit.
IPSBAR
Offset:
0x03D8 (RTCIENR)
Access: User read/write
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
R
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
W
Reset
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
R
0
0
0
0
0
0
0
0
0
0
HR
1HZ
DAY
ALM
MIN
SW
W
Reset
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Figure 8-8. RTC Interrupt Enable Register (RTCIENR)
Table 8-8. RTCIENR Field Descriptions
Field
Description
31-6
Reserved, should be cleared.
5
HR
Hour interrupt enable bit. This bit enables/disables an interrupt when the hour counter of the real-time clock
increments.
0 The 1-hour interrupt id disabled.
1 The 1-hour interrupt is enabled.
4
1HZ
1 Hz interrupt enable bit. This bit enables/disables an interrupt when the second counter of the real-time clock
increments.
0 The 1 Hz interrupt is disabled.
1 The 1 Hz interrupt is enabled.
3
DAY
Day interrupt enable bit. This bit enables/disables an interrupt when the hours counter rolls over from 23 to 0
(midnight rollover).
0 The 24-hour interrupt is disabled.
1 The 24-hour interrupt is enabled.
2
ALM
Alarm interrupt enable bit. This bit enables/disables the alarm interrupt.
0 The alarm interrupt is disabled.
1 The alarm interrupt is enabled.
1
MIN
Minute interrupt enable bit. This bit enables/disables an interrupt when the RTC minute counter increments.
0 The 1-minute interrupt is disabled.
1 The 1-minute interrupt is enabled.
0
SW
Stopwatch interrupt enable; enables/disables the stopwatch interrupt. The stopwatch counts down and
remains at decimal -1 until it is reprogrammed. If this bit is enabled with -1 (decimal) in the STPWCH register,
an interrupt is posted on the next minute tick.
Bit description
1 = Stopwatch interrupt is enabled.
0 = Stopwatch interrupt is disabled.
Because
of
an
order
from
the
United
States
International
Trade
Commission,
BGA-packaged
product
lines
and
part
numbers
indicated
here
currently
are
not
available
from
Freescale
for
import
or
sale
in
the
United
States
prior
to
September
2010:MCF52234CVM60,
MCF52235CVM60