Issue/Rev. 0.2 (12/12)
MN0M023 • Page 83
Device Functions Proline Promass 83
7 Block OUTPUTS
OUTPUT SIGNAL
(continued)
Example for active output circuit (ACTIVE):
With an active circuit, the internal power supply is 24 V.
The frequency output is short-circuit proof.
A0004691
m
= 24 V DC internal power supply
n
= Short-circuit proof output
The signal levels are to be seen as analogous to the passive circuit.
The following applies for the output configuration
ACTIVE-POSITIVE
:
In the quiescent state (at zero flow), the output signal level at the terminals is 0 V.
A0004694
In the operating status (flow present), the output signal level changes from 0 V to a
positive voltage level.
A0004692
The following applies for the output configuration
ACTIVE-NEGATIVE
:
In the quiescent state (at zero flow), the output signal level at the terminals is at a positive
voltage level.
A0004693
In the operating status (flow present), the output signal level changes from a positive
voltage level to 0 V.
A0004710
Function description
OUTPUTS
o
PULSE/FREQUENCY OUTPUT (1...2)
o
CONFIGURATION (FREQUENCY)
➀
➁
+
-
=
1 5
8 3
7
U
t
24 V
0 V
U
t
24 V
0 V
U
t
24 V
0 V
t
U
24 V
0 V