3 Block MEASURED VARIABLES
Device Functions Proline Promass 83
3.1
Group MEASURING VALUES
3.1.1
Function group MAIN VALUES
MEASURED
VARIABLES
A
MEASURING VALUES
AAA
MAIN VALUES
000
Function description
MEASURED VARIABLES
o
MEASURING VALUES
o
MAIN VALUES
!
Note!
• The engineering units of all the measured variables shown here can be set in the “SYSTEM UNITS” group.
• If the fluid in the pipe flows backwards, a negative sign prefixes the flow reading on the display.
MASS FLOW
(0000)
The currently measured mass flow appears on the display.
Display:
5-digit floating-point number, including unit and sign
(e.g. 462,87 kg/h; –731.63 lb/min; etc.)
VOLUME FLOW
(0001)
The calculated volume flow appears on the display. The volume flow is derived from the
measured mass flow and the measured density of the fluid.
Display:
5-digit floating-point number, including unit and sign
(e.g. 5.5445 dm
3
/min; 1.4359 m
3
/h; –731.63 gal/d; etc.)
CORRECTED VOLUME
FLOW
(0004)
The calculated corrected volume flow appears on the display. The calculated corrected
volume flow is derived from the measured mass flow and the reference density of the
fluid (density at reference temperature, measured or fixed entry).
Display:
5-digit floating-point number, including unit and sign
(e.g. 1.3549 Nm
3
/h; 7.9846 scm/day; etc.)
DENSITY
(0005)
The currently measured density or its specific gravity appears on the display.
Display:
5-digit floating-point number, incl. unit, corresponds to 0.1000 to 6.0000 kg/dm
3
(e.g. 1.2345 kg/dm
3
; 993.5 kg/m
3
; 1.0015 SG_20 °C; etc.)
REFERENCE DENSITY
(0006)
The density of the fluid, at reference temperature, appears on the display. The reference
density can be calculated with the measured density or also specified via the function
FIXED REF. DENSITY (6461), (see page 127), or read in directly via the current input.
Display:
5-digit floating-point number, incl. unit, corresponds to 0.1000 to 6.0000 kg/dm
3
(e.g. 1.2345 kg/dm
3
; 993.5 kg/m
3
; 1.0015 SG_20 °C; etc.)
TEMPERATURE
(0008)
The currently measured temperature appears on the display.
Display:
max. 4-digit fixed-point number, including unit and sign
(e.g. –23.4 °C; 160.0 °F; 295.4 K; etc.)
PRESSURE
(0009)
The currently measured pressure appears on the display. This function is not available
unless “pressure” was selected in the ASSIGN CURRENT INPUT function (5200).
Display:
max. 4-digit fixed-point number, including unit and sign