Issue/Rev. 0.2 (12/12)
Page 42
•
MN0M023
5 Block USER INTERFACE
Device Functions Proline Promass 83
5.2.2
Function group MULTIPLEX
USER INTERFACE
C
CONTROL
CAA
MAIN LINE
CCA
CONFIGURATION
220
MULTIPLEX
222
Function description
USER INTERFACE
o
MAIN LINE
o
MULTIPLEX
ASSIGN
(2220)
Use this function to define the second reading to be displayed in the main line alternately
(every 10 seconds) with the value defined in the ASSIGN function (2200).
Options (standard):
OFF
MASS FLOW
MASS FLOW IN %
VOLUME FLOW
VOLUME FLOW IN %
CORRECTED VOLUME FLOW
CORRECTED VOLUME FLOW IN %
DENSITY
REFERENCE DENSITY
TEMPERATURE
ACTUAL CURRENT (1...3)
ACTUAL FREQUENCY (1...2)
TOTALIZER (1...3)
ACTUAL CURRENT INPUT
Factory setting:
OFF
Advanced options with optional software package BATCHING:
BATCH NAME (“BATCH # 1” or “BEER 330”, etc.)
BATCH QUANTITY (overall quantity to be batched)
BATCH COUNTER (batching processes carried out)
BATCH SUM (effective total batching quantity)
!
Note!
The options given in the BATCHING software package always refer to the batching
selected (“BATCH # 1”, “BATCH # 2”, etc.) in the BATCH SELECTOR function
(page 147). Example: If BATCH # 1 was selected in the BATCH SELECTOR function
(7200), then only the values from BATCH # 1 (batch name, batch quantity etc.) can be
displayed.
Advanced options with optional software package CONCENTRATION:
TARGET MASS FLOW
% TARGET MASS FLOW
TARGET VOLUME FLOW
% TARGET VOLUME FLOW
CORRECTED TARGET VOLUME FLOW
CARRIER MASS FLOW
% CARRIER MASS FLOW
CARRIER VOLUME FLOW
% CARRIER VOLUME FLOW
CORRECTED CARRIER VOLUME FLOW
% BLACK LIQUOR
°BAUME
°API
°PLATO
°BALLING
°BRIX
OTHERS (_ _ _ _ flexible concentration)
(continued on next page)