Errors occurring when configuring and setting the parameters of the fieldbus communicator and
the connected pyrometer modules as well as external errors are reported by the communicator
via channel specific diagnostic.
In productive data exchange between the I/O controller and the fieldbus Endurance
®
PROFINET IO, one byte IOPS process data qualifiers are available for each module providing
information of the validity of the pyrometer module data (good/ bad). In the event of an error
occurs during operation, the problem-indicator in APDU-Status is set by the communicator and
a diagnostic alarm is additionally transmitted.
8.3.5.1. The error bits of the pyrometer status register (Error code)
Bit
Description
0
Heater temperature over range
1
Heater temperature under range
2
Internal temperature over range
3
Internal temperature under range
4
Wide band detector failure
5
Narrow band detector failure
6
Energy too low
7
Attenuation for failsafe too high
8
Attenuation to activate relay too high
9
Two color temperature under range
10
Two color temperature over range
11
Wide band temperature under range
12
Wide band temperature over range
13
Narrow band temperature under range
14
Narrow band temperature over range
15
Alarm
16
Video overflow
17
Profinet not ready
18
Heater not ready
8.4. Ethernet/IP (Communication Option 2)
Has to be properly described, when all details are clarified
8.4.1. Description
Has to be properly described, when all details are clarified
8.4.2. I/O Device Configuration
Has to be properly described, when all details are clarified
8.4.2.1. GSD File
Has to be properly described, when all details are clarified
Содержание endurance series
Страница 4: ......
Страница 8: ...iv...
Страница 10: ...vi...
Страница 24: ...Endurance Series Users Manual 12 3 4 1 1 Measurement Spot Size Diagrams for F0 Narrow Focus Option...
Страница 25: ...Innovative High Temperature Fiber Optic Infrared Pyrometers Technical Data 13...
Страница 26: ...Endurance Series Users Manual 14 3 4 1 2 Measurement Spot Size Diagrams for F1 Close Focus Option...
Страница 27: ...Innovative High Temperature Fiber Optic Infrared Pyrometers Technical Data 15...
Страница 28: ...Endurance Series Users Manual 16 3 4 1 3 Measurement Spot Size Diagrams for F2 Infinity Focus Option...
Страница 69: ...Innovative High Temperature Fiber Optic Infrared Pyrometers Signal Processing 57 defaults are restored...