Endurance® Series
Users Manual
88
12. Addendum
12.1. Determination of Slope (for 2
– color operation)
The following slope settings are approximate and will vary depending on the metal alloy and
surface finish, as well as the application. These are supplied here as examples.
Set the slope to approximately 1.000 for measuring the following metals with oxidized surfaces:
• Stainless Steel • Cobalt
• Steel
• Iron
• Nickel
Set the slope to approximately 1.060 for measuring the following metals with smooth, clean,
unoxidized surfaces:
• Iron
• Nickel
• Tantalum
• Stainless Steel • Rhodium
• Tungsten
• Cobalt
• Steel
• Molybdenum
• Platinum
Molten iron also has an approximate slope setting of 1.060.
How to determine slope?
The most effective way to determine and adjust the slope is to take the temperature of the
material using a probe sensor such as an RTD, thermocouple, or other suitable method. Once
you determine the actual temperature, adjust the slope setting until the sensor’s temperature
reads the same as the actual temperature reading. This is the correct slope for the measured
material.
12.2. Percentage of allowed signal reduction
show each sensor model’s percentage of allowed signal reduction at
all temperatures. Refer to these graphs to estimate what percentage of target area must be
visible to the sensor at temperatures below the minimum temperature (95% attenuation) as
shown in this manual.
sensors see polluted atmosphere and dirty windows and lenses as
a reduction in energy and give much lower than actual temperature
readings!
Figure 63: Model L Percentage of Allowed Signal Reduction
Model L – up to 95% allowed signal reduction
800°C (1472°F) to 1800°C (3272°F)
Att
en
ua
tion
Fac
tor
Target Temperature
Содержание endurance series
Страница 4: ......
Страница 8: ...iv...
Страница 10: ...vi...
Страница 24: ...Endurance Series Users Manual 12 3 4 1 1 Measurement Spot Size Diagrams for F0 Narrow Focus Option...
Страница 25: ...Innovative High Temperature Fiber Optic Infrared Pyrometers Technical Data 13...
Страница 26: ...Endurance Series Users Manual 14 3 4 1 2 Measurement Spot Size Diagrams for F1 Close Focus Option...
Страница 27: ...Innovative High Temperature Fiber Optic Infrared Pyrometers Technical Data 15...
Страница 28: ...Endurance Series Users Manual 16 3 4 1 3 Measurement Spot Size Diagrams for F2 Infinity Focus Option...
Страница 69: ...Innovative High Temperature Fiber Optic Infrared Pyrometers Signal Processing 57 defaults are restored...