4.3.2.7 Inspection of Flap Control Microswitches
4.3.2.7.1 Type of Maintenance
Line
4.3.2.7.2 Minimum Level of Certification
Repairman, Light Sport Aircraft-Maintenance (RLSA-M) or higher.
4.3.2.7.3 Procedure
Tools required:
Screwdriver
1
pcs
Inspection of the up limit microswitches
С
9997198B (Miniature switch). Fig. 10.
Fig. 10
1. Set the flaps in 35° position.
2. Set the flap control switch in the flap max up position.
3. While the actuator is moving press the up limit switch by a screwdriver. The actuator must stop
then.
4. Release the up limit switch. The actuator must move up to the flap max up position.
5. Replace the Microswitch
С
9997198B (Miniature switch), if it does not work per items 3 and 4.
Inspection of the down limit switch (Fig. 10):
1. Set the flaps in the flap max up position (-6° or -12°).
2. Set the flap control switch in 35° position.
3. While the actuator is moving press the down limit switch by a screwdriver. The actuator must stop
then.
4. Release the up limit switch. The actuator must move down to 35° position.
5. Replace the Microswitch
С
9997198B (Miniature switch), if it does not work per items 3 and 4.