Maintenance and Inspection Procedures Manual
Type:
CT
Series:
CTLS
LSA
Page: 8-4
AF 04800001
Revision No. 3
Date: 14 Sep 2008
Fig. 5
•
Pass it through the tube
С
9993190
Н
PTFE tube 4.0x6.0 mm into the engine compartment.
•
Attach the cable
С
9997065
В
(Steel rope 7x7 1 mm) to the heating Cabin heater choke
КА
7040200 as shown by arrows at Fig. 4, secure the cable by
С
9997816
С
Cable stop 1806-
Z ni.
4. Check the Cabin heater choke
КА
7040200 for operating according to the item 2. If positive,
continue from item 7.
5. If, while the handle is pulled, the choke is OFF, do the following
a. Release
the
stop
С
9997816
С
(Cable stop 1806-Z ni) a little by a screwdriver and tighten the
cable
С
9997065
В
(Steel rope 7x7 1 mm).
NOTE: the stop can move along the cable, when the bolt is not tightened.
b. Secure stop 9997816
С
(Cable stop 1806-Z ni) position by a screwdriver.
c. Proceed to item 4.
6. If the choke
КА
7040200 is at OFF position and the handle is not fully pulled out, do the following.
a. Mark on the handle length it can be pulled out more (distance from the bracket to the cotter-
pin in the handle). Fig. 6.
Fig. 6
b. Release the stop
С
9997816
С
(Cable stop 1806-Z ni) unscrewing the bolt in the stop by a
screwdriver.
c. Move the stop
С
9997816
С
(Cable stop 1806-Z ni) on
а
distance towards the tip of the cable
С
9997065
В
(Steel rope 7x7 1 mm) and secure the stop
С
9997816
С
(Cable stop 1806-Z ni)
by a screwdriver.