![FLIGHT DESIGN CTLS Series Скачать руководство пользователя страница 82](http://html1.mh-extra.com/html/flight-design/ctls-series/ctls-series_maintenance-and-inspection-procedures-manual_2305270082.webp)
Maintenance and Inspection Procedures Manual
Type:
CT
Series:
CTLS
LSA
Page: 4-45
AF 04800001
Revision No. 3
Date: 14 Sep 2008
4.3.1.7.5 Measuring Aileron Deflection
Any adjustment of the aileron control system must be documented in an adjustment report. You can find
the template starting the nominal values and allowable tolerances in the Appendix of this maintenance
manual.
Step 1. Set flaps to upper position -6
°
or -12
°
(-6° is required for CTLS registered within USA as LSA
aircraft). In this position the trailing edges of aileron and flaps must coincide (see photo 1).
Photo 1
Step 2. Put the pattern on the flap (see photo 6). Deflect the aileron in upper position by control stick.
Place between markers on the pattern must coincide with the aileron trailing edge (see photo 2). Markers
on the pattern define boundary values of maximum deflection angle.
Photo 2
Using ruler instead of deflection template:
Measure distance between same corners (lowest or topmost) on the rear edge of the flap and on the
aileron (see photo 2.1).