Maintenance and Inspection Procedures Manual
Type:
CT
Series:
CTLS
LSA
Page: 8-7
AF 04800001
Revision No. 3
Date: 14 Sep 2008
Fig. 9
a. Unscrew the bolt by a cross-screwdriver or wrench with header 7 and release the clamp
С
9997723 Clamp 40-60 that secures the hose
С
9993188 (AERODUCT tube CEET-7 1-
3/4 ID) near the heating Cabin heater choke
КА
7040200. Fig. 9.
b. Unscrew the bolt
С
9996053 (Bolt DIN 912 M6x10-8.8) by a hex-nut wrench 5 and
remove the shield
КА
5030001 (Protection plate, left).
c. Unscrew the bolt
С
9996053 (Bolt DIN 912 M6x10-8.8) by a hex-nut wrench 5 and
remove the shield
КА
5030002 (Protection plate, right).